beautypg.com

Warning, Install vent system, Install cord bracket and casters – Whirlpool Conservator CEDC392JQ0 User Manual

Page 8

background image

8

Determine vent length

1. Select the route that will provide the straightest and most

direct path outdoors. Plan the installation to use the fewest
number of elbows and turns. When using elbows or making
turns, allow as much room as possible. Bend vent gradually
to avoid kinking. Avoid 90° turns when possible.

2. Determine vent length.

The maximum length of the exhaust system depends upon:

The type of vent (rigid metal or flexible metal).

The number of elbows used.

Type of hood.

Recommended hood styles are shown here.

The angled hood style (shown following) is acceptable.

See the exhaust vent length chart that matches your hood
type for the maximum vent lengths you can use.

Exhaust systems longer than specified will:

Shorten the life of the dryer.

Reduce performance, resulting in longer drying times and
increased energy usage.

3. Determine the number of elbows you will need.

IMPORTANT: Do not use vent runs longer than specified in the
Vent Length Chart.

In the column listing the type of metal vent you are using (rigid
metal or flexible metal), find the maximum length of metal vent on
the same line as the number of elbows.

Vent Length Chart

Install Vent System

1. Before installing the vent system, be sure to remove the wire

exhaust guard that is located at the exhaust outlet.

2. Install exhaust hood. Use caulking compound to seal exterior

wall opening around exhaust hood.

3. Connect vent to exhaust hood. Vent must fit inside exhaust

hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.

4. Run vent to dryer location. Use the straightest path possible.

See “Determine vent length.” Avoid 90º turns. Use clamps to
seal all joints. Do not use duct tape, screws or other fastening
devices that extend into the interior of the vent to secure
vent.

Install Cord Bracket and Casters

Do not move dryer into its final position until the following steps
have been performed.

Install cord bracket

1. Remove tape from the power cord and the rear panel.

A. Louvered style
B. Box hood style

better

good

4"
(10.2 cm)

4"
(10.2 cm)

B

A

4"

(10.2 cm)

2½"

(6.4 cm)

Number of
90º turns
or elbows

Type of
vent

Box or
louvered
hoods

Angled
hoods

0

Rigid metal
Flexible metal

36 ft (11 m)
28 ft (8.5 m)

26 ft (7.9 m)
22 ft (6.7 m)

1

Rigid metal
Flexible metal

26 ft (7.9 m)
18 ft (5.5 m)

16 ft (4.9 m)
12 ft (3.7 m)

2

Rigid metal
Flexible metal

16 ft (4.9 m)
8 ft (2.8 m)

6 ft (1.8 m)
2 ft (0.6 m)

WARNING

Excessive Weight Hazard

Use two or more people to move and install dryer.

Failure to do so can result in back or other injury.