Plan vent system – Whirlpool Conservator CEDC392JQ0 User Manual
Page 7
7
An exhaust hood should cap the vent to prevent rodents and
insects from entering the home.
Exhaust hood must be at least 12" (30.5 cm) from the ground or
any object that may be in the path of the exhaust (such as
flowers, rocks or bushes, etc.).
If using an existing vent system, clean lint from the entire length
of the system and make sure exhaust hood is not plugged with
lint. Replace any plastic or metal foil vent with rigid metal or
flexible metal vent.
Plan Vent System
Typical installations vent the dryer from the rear of the dryer.
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for
your installation. Two close-clearance installations are shown.
Refer to the manufacturer’s instructions provided with the vent
system.
NOTE: The following kits for close clearance alternate
installations are available for purchase. For ordering information
see “Assistance or Service.”
■
Over-The-Top Installation:
Part Number 4396028
■
Periscope Installation (for use with dryer vent to wall vent
mismatch):
Part Number 4396037 - for mismatch of 0" (0 cm) to
18" (45.72 cm)
Part Number 4396011 - for mismatch of 18" (45.72 cm) to
29" (73.66 cm)
Part Number 4396014 - for mismatch of 29" (73.66 cm) to
50" (127 cm)
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
A. Exhaust hood
B. Flexible metal vent or rigid metal vent
C. Elbow
A
B
C
A. Over-The-Top installation (also available with
one offset elbow)
B. Periscope installation
A
B