CCS – Cellar Pre-Chill Set Point: This parameter is set at 52°f, but can be adjusted to a set point

between 45°f - 67°f.

bLL/Act – Compressor Off or On for Low (bLL) or High (Act) Temperature Alarm: These parameters

are set at “n”. With this parameter set at “n” the refrigeration system will continue to operate nor-

mally, if there is a High or Low temperature Alarm. To change this parameter, change the setting to

“y”, and the compressor/refrigeration system will shut off during a High or Low temperature Alarm.

Con/Cof – Compressor On time (Con) and Off time (Cof) with a Probe 1 failure/Alarm. These pa-

rameters are set at Con 40 min/Cof 10 min. In the event that there is a Probe 1 failure/Alarm, the

compressor/refrigeration system automatically starts a predetermined ON/OFF cycle, which is con-

trolled by the Con and the Cof parameters. The customer can adjust these parameters to maintain

the desired Bottle Probe temperature. During a Probe 1 failure/Alarm, the Bottle Probe tempera-

ture can be monitored by pressing the Up or Down arrow to view the High and Low Temperature

History.

Hes – Differential for Energy Reduction – This parameter is set at 4, which results in a set point of

52°f during the Energy Reduction mode. A decrease in this setting will decrease the set point, and

an increase in this feature will increase the set point.

AUX

“AUX” indicates that the condenser fan is running. Pressing the “AUX” button on the control panel

will turn it off.

Alarm Codes

Message

Cause

Outputs

“P1”

Room probe failure

Toggle “Con” and “COF” based on your temperature needs

“P2”

Evaporator probe failure

Defrost end is timed

“P3”

Condenser probe failure

Outputs unchanged

“HA”

Max bottle probe temp alarm

Outputs unchanged

“LA”

Min bottle probe temp alarm

Outputs unchanged

“HA2”

Condenser high temperature

It depends on the “Ac2” parameter

“LA2”

Condenser low temperature

It depends on the “bLL” parameter

“EA”

External alarm

Outputs unchanged

“POF”

Keypad locked

Hold “Up” and “Down” buttons for 3 to 5 seconds to disable,

“PON” should appear