Button
Normal Functions
ON/OFF
•
The ON/OFF button allows the customer the convenience of turning the refrigeration system
ON or OFF, from the control panel. This feature does not disconnect power from the unit, and
the condenser fan will continue to run in the OFF position. In order for the power to be shut off
from the unit, the power cord must be unplugged from the wall receptacle.
•
Press the ON/OFF button once for button application.
Up and
Down
Arrows
•
Use these buttons to scroll up or down the CPSM menu.
•
Displays the Highest and Lowest temperature sensed by the Bottle Probe. This feature allows
the customer instant access to the recorded data applicable to the Bottle Probe Temperatures,
it can be easily reset to reflect current temperatures.
1. Press the “UP” arrow, or the “Down” arrow once, and the Highest or Lowest Temperature (Hi/Lo)
sensed by the Bottle Probe, will be displayed.
2. To reset the Hi/Lo, press and hold the “Set” button when the Hi/Lo value is displayed on the
Digital Display, continue to hold the “Set” button until “rst” appears on the digital display and then
blinks. This will erase the past recorded “Temperature Data History” and start recording, from the
current time and temperature, forward. Temperatures displayed would reflect Bottle Probe Tem-
peratures from that point in time, and beyond.
3. The Hi/Lo feature should be reset at initial “Start-Up” and after the Cellar or Cabinet has obtained
normal operating temperatures, which is generally 55°F.
Cellar
PreChill
(CPC)
The CPC Feature is activated by pressing the Up button for 3-5 seconds, and the CPC logo will be
displayed on the digital display. The CPC feature can be terminated by pressing the Up button for
3-5 seconds, or the feature will self terminate after 6 hrs.
1. The (CPC) Feature may be used to Pre-Chill the Cellar prior to loading it with Warm Product. The
feature will shift the Set Point down to a lower setting of 52°F, for the next 6 hours. After the 6 hour
time period, the Set Point will automatically return to the original Set Point.
2. The CPC feature can be conveniently adjusted to the customer’s specific needs, by accessing the
“Customer Preference Select Mode” (CPSM). See Customer Preference Select Mode Instructions.
Note: This feature is not available on the Remote Key Pad application.