INSTALLATION (continued)

5

4.

For Cook ‘N Hold warmers:

a. Verify that provided sealants are applied to the underside

of the warmer top flange prior to setting the unit into the

cutout.
b.

After

installation,

verify

that the tabs on the Wellsloks are

turned out to lock the warmer into the counter

c. Apply a thin bead of food-grade silicone sealant around the

flange to seal it to the counter.

d. Wellslok extension kits are available for installing warmers

in counter tops where the standard Wellslok would not

normally reach. The extension kit will adapt to counter

tops up to 1¾” thick.


ELECTRICAL INSTALLATION


1.

Refer to the product nameplate. Verify the electrical service

power. Voltage and phase must match the nameplate

specifications. Wiring the warmer to the wrong voltage can

severely damage the unit or cause noticeably decreased

performance.

2.

Available electrical service amperage must meet or exceed the

specifications listed on the specification sheet provided with the

warmer.

3.

Warmer and control unit must be connected to an appropriate

building ground. Ground connection will be marked “GND” or

” " .


NOTE: Wire gauge, insulation type and temperature rating , as

well as type, size and construction of conduit, must meet or exceed

applicable specifications of local codes and of the National

Electrical

Code.


E. PLUMBING

INSTALLATION


1.

IMPORTANT: All plumbing installations must be performed by

a

qualified

plumber.

2.

For units equipped with a DRAIN LINE: Some jurisdictions

may require an approved air gap or other back-flow

prevention device in the drain. It is the responsibility of the

plumber to determine such requirement, to provide and

properly install the required device.

NOTE: Damage caused by
leaks due to improper
installation is NOT covered by
warranty.

CAUTION:

ELECTRIC
SHOCK HAZARD

The ground lug of this
appliance must be connected
to a suitable building ground.

IMPORTANT:
Contact a licensed electrician
to install and connect
electrical power to the
appliance.


IMPORTANT:
Damage due to being
connected to the wrong
voltage or phase is NOT
covered by warranty.


IMPORTANT: Electrical
installation other than as
specified on the specification
sheet will void the UL listing,
and may void the warranty.

NOTE: Plumb connections
must be made in compliance
with all Federal, State and
Local Plumbing Codes and
Ordinances.

015

303740

Op

M

anual

for Built-In

H

W

W

a

rmer

s

This manual is related to the following products: