TROUBLESHOOTING SUGGESTIONS

9

SYMPTOM

POSSIBLE CAUSE

SUGGESTED REMEDY

No power to warmer

Circuit breaker off or tripped

Reset circuit breaker

Warmer will not heat

Temperature control not set

Set control to desired temperature

Warmer trips circuit breaker

Wet insulation

Verify flange-to counter seal is
sound, or reseal with food-grade
silicone sealant

Pan leaking or other internal
damage

Contact your Authorized Wells
Service Agency for repairs

Internal damage

Contact your Authorized Wells
Service Agency for repairs

Warmer slow to heat

Mineral deposits on pan acting as
a insulator

Clean pan(s) with Wells Delime
Cleaner

Wired to wrong voltage

Verify supply voltage - must
match voltage on warmer
nameplate

Drain-equipped unit will not hold
water

Drain valve not fully closed

Check drain valve for debris and
close fully

Drain valve damaged or pan(s)
leaking

Contact your Authorized Wells
Service Agency for repairs

There are no user-serviceable
components in the control unit or
in the pan shroud. In all instances
of damage or malfunction, contact
your Authorized Wells Service
Agency for repairs.