beautypg.com

Packing replacement procedures – Wagner SprayTech 3000 User Manual

Page 22

background image

FIGURE 5

Packing Replacement Procedures

FIGURE 6

20

3. Push the two bolts (100-318) through the tube spacers

(331-074) & screw into the cover assembly (331-234).

Using a 1/2” wrench, tighten the two bolts evenly

(alternating between them) until you reach 20 ft-lbs.

4. Reassemble lower suction valve assembly by placing

the suction seat (331-409) O-ring (106-011), suction

ball (331-030) and suction ball guide (331-029) in the

suction nut (331-034) & screw onto the fl uid pump body.

5. Start the machine & operate slowly to check the piston

rod for binding. Adjust the bolts, holding the fl uid

pump body to the cover assembly, if necessary. This

will eliminate any binding.

76 Tighten packing nut clockwise until resistance is felt

against the Belleville Springs, then go 3/4 of a turn

more. Put fi ve drops of Airlessco Throat Seal Oil

into the packing nut.

7. Run the machine at full pressure for several minutes.

Release the pressure by following the Pressure Relief

Procedure & readjust the packing nut per step 6 above.

8. Install the connecting rod safety shield

(Fig. 1 Part # 331-111) so that the small hole is in the

upper right hand corner.

This manual is related to the following products: