Field troubleshooting – Wagner SprayTech 3000 User Manual
Page 18
Field Troubleshooting
PROBLEM
CAUSE
SOLUTION
Unit doesn't prime
Airleak due to:
• Loose Suction Nut
• Tighten Suction Nut
• Worn O-Rings
• Replace O-Ring (106-011) on
suction seat, & O-Ring (106-
020) below suction seat
• Hole in Suction Hose
• Replace Suction Hose (331-290)
Stuck or Fouled Balls
Service outlet valve suction
assembly
Unit primes but has no
Pressure set too low
Turn up pressure
or poor pressure
Filter(s) are clogged
Clean or replace gun filter, inlet
filter and/or manifold filter
Outlet Valve fouled/worn
Service outlet valve
Prime/Pressure Relief valve
Clean or replace primve valve
bypassing
Packings and/or piston worn
• Tighten packing nut
• Repack unit
Unit does not maintain
Blown spray tip
Replace spray tip
good spraying pressure
Packings and/or piston worn
Repack unit
Upper Seat worn
Replace upper seat
16