Field Troubleshooting

PROBLEM

CAUSE

SOLUTION

Unit doesn't prime

Airleak due to:

• Loose Suction Nut

• Tighten Suction Nut

• Worn O-Rings

• Replace O-Ring (106-011) on

suction seat, & O-Ring (106-

020) below suction seat

• Hole in Suction Hose

• Replace Suction Hose (331-290)

Stuck or Fouled Balls

Service outlet valve suction

assembly

Unit primes but has no

Pressure set too low

Turn up pressure

or poor pressure

Filter(s) are clogged

Clean or replace gun filter, inlet

filter and/or manifold filter

Outlet Valve fouled/worn

Service outlet valve

Prime/Pressure Relief valve

Clean or replace primve valve

bypassing

Packings and/or piston worn

• Tighten packing nut

• Repack unit

Unit does not maintain

Blown spray tip

Replace spray tip

good spraying pressure

Packings and/or piston worn

Repack unit

Upper Seat worn

Replace upper seat