beautypg.com

Installation instructions, Warning, Unpacking – Whirlpool ACC082XR0 User Manual

Page 5

background image

5

To test your power supply cord:

1. Plug power supply cord into a grounded 3 prong outlet.

2. Press RESET.

3. Press TEST (listen for click; Reset button will trip and pop

out).

4. Press and release RESET (listen for click; Reset button will

latch and remain in). The power supply cord

is ready for

operation.

NOTES:

The Reset button must be pushed in for proper operation.

The power supply cord must be replaced if it fails to trip when
the test button is pressed or fails to reset.

Do not use the power supply cord as an off/on switch. The
power supply cord is designed as a protective device.

A damaged power supply cord must be replaced with a new
power supply cord obtained from the product manufacturer
and must not be repaired.

The power supply cord contains no user serviceable parts.
Opening the tamper-resistant case voids all warranty and
performance claims.

INSTALLATION INSTRUCTIONS

Unpacking

Remove packaging materials

Remove and properly dispose of packaging materials.
Remove tape and glue residue from surfaces before turning
on the air conditioner. Rub a small amount of liquid dish soap
over the adhesive with your fingers. Wipe with warm water
and dry.

Do not use sharp instruments, rubbing alcohol, flammable
fluids, or abrasive cleaners to remove tape or glue. These
products can damage the surface of your air conditioner.

Handle air conditioner gently.

1. Remove air conditioner from carton and place on cardboard.

2. Remove shipping screw from side wall of cabinet.

3. Pull off control knobs (on some models).

4. Remove front panel from air conditioner and set aside.

5. Remove ground screw and ground wire from front of air

conditioner base. Save ground screw.

6. Pull on handle to slide air conditioner out of cabinet. Place air

conditioner on cardboard.

NOTE: Do not lift, push, pull or remove any expanded
polystyrene (foam) from inside the air conditioner. It is not
packing material.

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death,
fire, or electrical shock.

WARNING

A. Shipping screw

WARNING

Excessive Weight Hazard

Use two or more people to move and install
air conditioner.

Failure to do so can result in back or other injury.

A

A. Green ground wire
B. Ground screw

A. Handle

A

B

+

+

+

A