beautypg.com

Whirlpool ACC082XR0 User Manual

Page 14

background image

14

Air conditioner power supply cord trips (Reset button
pops out)

Disturbances in your electrical current can trip (Reset
button will pop out) the power supply cord.
Press and
release RESET (listen for click; Reset button will latch and
remain in) to resume operation.

An electrical overloading, overheating, pinching or aging
can trip (Reset button will pop out) the power supply
cord.
After correcting the problem, press and release RESET
(listen for click; Reset button will latch and remain in) to
resume operation.

NOTE: A damaged power supply cord must be replaced with a
new power supply cord obtained from the product manufacturer
and must not be repaired.

Air conditioner seems to run too much

The current air conditioner replaced an older model. The
use of more efficient components may cause the air
conditioner to run longer than an older model, but the total
energy consumption will be less. Newer air conditioners do
not emit the “blast” of cold air you may be accustomed to
from older units, but this is not an indication of lesser cooling
capacity or efficiency. Refer to the efficiency rating (EER) and
capacity rating (in BTU/hr) marked on the air conditioner.

The air conditioner is in a heavily occupied room, or heat-
producing appliances are in use in the room.
Use exhaust
vent fans while cooking or bathing and try not to use heat-
producing appliances during the hottest part of the day. A
higher capacity air conditioner may be required, depending
on the size of the room being cooled.

Air conditioner cycles on and off too much or does not
cool

Mode is set to Power Saver. Use Power Saver only when
you are asleep or away from home, since the fan does not
circulate the room air continuously. Use Low, High or Turbo
for your best comfort.

The air conditioner is not properly sized for your room.
Check the cooling capabilities of your room air conditioner.
Room air conditioners are not designed to cool multiple
rooms.

The filter is dirty or obstructed by debris. Clean the filter.

The inside evaporator and outside condenser coils are
dirty or obstructed by debris.
See “Annual Maintenance.”

There is excessive heat or moisture (open container
cooking, showers, etc.) in the room.
Use a fan to exhaust
heat or moisture from the room. Try not to use heat-
producing appliances during the hottest part of the day.

The louvers are blocked. Install the air conditioner in a
location where the louvers are free from curtains, blinds,
furniture, etc.

The outside temperature is below 65°F (18°C). Do not try to
operate your air conditioner in the cooling mode when the
outside temperature is below 65°F (18°C).

The temperature of the room you are trying to cool is
extremely hot.
Allow extra time for the air conditioner to cool
a very hot room.

Windows or doors to the outside are open. Close all
windows and doors.

The temperature set point is not at a cool enough setting.
Adjust the temperature set point to a cooler setting by
pressing the down arrow button. Set Fan Speed to Turbo.

Temperature on display does not match room
temperature

When the compressor and fan motor turn off during
Power Saver mode, or after you turn off the unit, a lower
temperature reading than the actual room temperature
may be displayed for a short period of time.
This lower
temperature reading is caused by the temperature sensor
being located close to the cold evaporator coil. The actual
room temperature will display within a few minutes.

Water drips from cabinet into your house

The air conditioner is not properly leveled. The air
conditioner should slope slightly downward toward the
outside. Level the air conditioner to provide a downward
slope toward the outside to ensure proper drainage. See the
Installation Instructions.

NOTE: Do not drill a hole into the bottom of the metal base
and condensate pan.