beautypg.com

Installation – Waterford Appliances T25-LP User Manual

Page 11

background image

Waterford TARA T25 Direct Vent Freestanding Gas Stove

11

INSTALLATION

RESIDENTIAL AND MANUFACTURED HOMES / MOBILE HOMES

MINIUMUM HORIZONTAL TERMINATION INSTALLATIONS

You will require the following components with your new Regency Rear Vent Direct Vent
Freestanding Gas Stove. Please review your product to make sure you have everything you need.
In the event that you are missing any part, contact your dealer.
Decorative brass or chrome trim kits are available from Simpson
Dura-Vent for their wall thimbles, as well as a square
wall thimble cover.

Planning Your venting Installation

See page 9 for Exterior Vent Termination
requirements.
The T25 is approved for a
minimum horizontal termination with the Regen-
cy Riser Vent Kit. See the diagram for minimum
and maximum pipe lengths.

When planning your installation, it will be nec-
essary to select the proper length of vent pipe
for your particular requirements. Determine the
minimum clearance to combustibles from the
rear of the unit to the wall. It is also important to
note the wall thickness. Before cutting the vent
hole through the wall ensure that ALL vent and
termination clearances (see page 10) will be
met.

The venting arrangements shown on the dia-
gram, have a minimum of 75% (flue loss)
efficiency with Fan Off, as required for man-
ufactured homes. (Actual efficiency may be as
high as 85%.)

*If this is an outside corner, the minimum dis-
tance between the vent and the outside corner
is 6" (15cm). See "F" on the diagram on page 10.

NOTE: Ensure compliance with the outside vent
terminal location before cutting hole as both
dimensions must be met.

Note: These are the minimum pieces re-

quired. Other parts may be required
for your particular installation.

Minimum components for a Horizontal Installation:
640-944

Horizontal Termination Kit which includes:
1 946-201

6-5/8" Dia. x 18" Black Pipe

1 946-207

4" Dia. x 18" Aluminum Vent

1 946-202

Wall Penetration Heat Shield (Wall Thimble) (2 pcs)

1 640-530

Riser Vent Terminal

1 640-545

Decorative Wall Trim (Black)

1 948-128

Tube Mill-Pac
Screws

945G*

1 45

o

Elbow

946-219

1 Adapter

Optional Components:
946-204

45

o

Elbow - 6-5/8" Black pipe

and 4" Aluminum Vent

946-205

Vinyl Siding Shield for Riser Vent
Terminal

946-208/P

Vent Guard

940

Square Wall Thimble Cover*

981

Snorkel Termination (36")*

982

Snorkel Termination (14")*

942

Wall Penetration
Heat Shield*

* Simpson Dura-Vent components

This manual is related to the following products: