MAINTENANCE-TROUBLESHOOTING

86302100 CLIPPER DUO 10/02/07

4-8

PROBLEM CAUSE

SOLUTION

Is the cord plugged in.

Plug in cord.

Circuit breaker tripped in building.

Reset breaker.

Faulty switch.

Call for service.

No Power, Nothing

Runs

Faulty power cord or pigtail.

Call for service.

Vacuum circuit breaker tripped.

Reset breaker.

Faulty main vacuum switch.

Call for service.

Loose wiring.

Call for service.

Vacuum Motor Will Not

Run

Faulty vac motor.

Call for service.

Debris lodged in vac shoe.

Remove debris from vac shoe.

Dome gasket defective or missing.

Replace as necessary.

Vacuum hose cracked or hose cuff loose.

Replace or repair as necessary.

Vacuum Motor Runs

But Suction Is Poor

Recovery tank full / float ball stuck in the

up position.

Turn off vac motor. Drain and rinse

recovery tank.

Pump switch in intermittent position.

Turn to continuous or use buttons on

handle

Jets clogged or missing.

Clean using a vinegar /water solution or

replace.

Solution filter clogged.

Drain solution tank and clean solution

filter.

Poor Or No Water Flow

(Carpet Is Streaky)

Faulty solenoid.

Call for service.

Main switch off or in hand tool mode.

Turn main switch to machine mode.

Brush circuit breaker tripped.

Reset circuit breaker.

Brush belt broken.

Replace as necessary.

Brush Does Not Spin

Faulty brush motor.

Call for service.