Failure to adhere to the guidelines on this page can result in
severe personal injury, death or substantial property damage.

Boiler service and maintenance —

To avoid electric shock,

disconnect electrical supply

before

performing maintenance.

To avoid severe burns,

allow boiler to cool

before performing

maintenance.

You must

maintain

the boiler as outlined in the manual and have the

boiler

started up and serviced at least annually by a qualified

service technician

to ensure boiler/system reliability.

Boiler operation —

Do not block flow of combustion or ventilation

air

to boiler. This boiler

is equipped with a control which will automatically shut down the boiler
should air or vent be blocked. If vent or air blockage is easily accessible
and removable, remove it. The boiler should attempt to restart within an
hour. If blockage is not obvious or cannot be removed, have the boiler
and system checked by a qualified service technician.

Should

overheating

occur

or gas supply fail to shut off

, do not

turn off or disconnect electrical supply to pump. Instead,

shut off the

gas supply

at a location

external to the appliance

.

Do not use this boiler if any part has been under water

.

Immediately call a qualified service technician to inspect the boiler and to
replace any part of the control system and any gas control, which has
been under water.

Boiler water —

DO NOT use

petroleum-based

cleaning or sealing compounds in

boiler system. Water seal deterioration will occur, causing leakage between
sections and damage to heating system components. This can result in
substantial property damage.

DO NOT use "

homemade cures

" or "

boiler patent medicines

".

Serious damage to boiler, personnel and/or property may result.

Continual fresh

makeup water will reduce boiler life

. Mineral

build-up in sections reduces heat transfer, overheats cast iron, and causes
section failure. Addition of oxygen and other gases can cause internal
corrosion. Leaks in boiler or piping must be repaired at once to prevent
makeup water.

Do not add cold water to hot boiler

. Thermal shock can cause

sections to crack.