Common problems and solutions

(continued)

Symptom

Common Causes

Possible Corrections

Popping or percolating

noise heard in boiler

Mineral deposits in sections due to
constant use of makeup water

Call qualified service technician to de-lime
boiler, if necessary. In some cases,
deposits will be too heavy to remove with
de-liming procedures.

Have qualified service technician repair
leaks to eliminate need for constant
makeup water.

Incorrect pH of boiler water

Call qualified service technician to check
pH level and correct. pH should be
maintained between 7.0 to 8.5.

Insufficient water flow through
boiler

Check all valves to and from boiler. Return
to proper setting.

Confirm circulator size.

Metal flakes found in vent

outlet or vent starter tee —

flueway corrosion

Contaminated combustion air
supply — See page 4 in this
manual.

Remove any contaminating products. See
page 4 in this manual.

Provide outside air for combustion. Kit
available through Weil-McLain distributor.
Have qualified service technician pipe-up
kit.

Condensation of combustion
gases in boiler sections

Have qualified service technician check
operation of mixing system. Repair/replace
if necessary.

Some radiators or

baseboard units do not

heat or are noisy

Air in system

Bleed air from system through air vents in
radiators or baseboard units.

Low system pressure

Fill to correct pressure.

Check for leaks in boiler or piping. Have
qualified service technician repair at once.

High limit set too low

Adjust high limit to higher setting.