beautypg.com

Owner’s manual, Operating stove with burner system, Continued – Vanguard Heating SDVBN(A) User Manual

Page 25: Optional remote operation, Thermostat control operation, Ghrc series operation, Ghrct series operation

background image

25

105499

OWNER’S MANUAL

1.

After lighting, let pilot flame burn for
about one minute. Turn gas control
knob on the control valve to ON posi-
tion. Turn variable control knob any-
where between HI and LO. Slide the
selector switch to the REMOTE posi-
tion.

Note:

The burners may light if

hand-held remote ON button was on
when selector switch was last turned
off. You can now turn the burners on
and off with either optional hand-held
remote control unit.

IMPORTANT:

Do not leave the se-

lector switch in the REMOTE posi-
tion when the pilot is not lit. This will
drain the battery.

IMPORTANT:

Be sure to press the

ON/OFF buttons on the hand-held
remote control unit for up to 3 sec-
onds to assure proper operation.

OPTIONAL REMOTE

OPERATION

Note:

All remote control accessories must

be purchased separately (See Accessories
on page 33). Follow instructions included
with the remote control.

Thermostat Control Operation

(Optional GHRCT Only) The thermostat
control setting on the remote control unit
can be set to any comfort level between HI
and LO. The burners will turn on and off
automatically to maintain the comfort level
you select. The ideal comfort setting will
vary by household depending upon the
amount of space to be heated, the output of
the central heating system, etc.

NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See

Lighting

Instructions, page 24 .

OPERATING STOVE
WITH BURNER
SYSTEM

Continued

Continued

GHRC Series Operation:

2a. Press the ON/OFF button to turn the

burners on and off. When turning
burners off, the pilot will remain lit.

GHRCT Series Operation:

2b. Select the MAN (manual) or AUTO

button on the hand-held remote con-
trol unit (see Figure 60).
In manual mode, turn burners on

or off by pressing the ON or OFF
buttons on the hand-held remote
control unit.

• In auto mode, the room temperature

is controlled by the thermostat in the
hand-held remote control unit. To
increase the room temperature,
press the top arrow of the TEMP
button. To lower the room tempera-
ture, press the bottom arrow of the
TEMP button. At higher settings the
burner system will run more.

Figure 59 - Setting the Selector Switch,
Gas Control Knob, and Variable Control
Knob for Remote Operation

TEMP

STATUS

HI

LO

MAN

ON

AUTO

OFF

Figure 60 - Hand-Held Thermostat Remote Control Unit Selections
(GHRCT Only)

Shows Temperature
Setting

Allows Burners to be
Turned On and Off
with the Hand-Held
Remote Unit

The Burner System
will Automatically
Cycle between Pilot
and the Heat Setting
that has been
Selected

Increases Room
Temperature

Decreases Room
Temperature

Turns Burners On
and Off

Shows Current
Operation Mode

IMPORTANT:

This remote control

has been specially engineered to take
an air temperature sample every 5.5
minutes in auto mode. It will not re-
spond immediately to the tempera-
ture setting being turned up or down.

IMPORTANT:

The hand-held remote

control unit must be near the stove
but not extremely close to it. The
thermostat on the hand-held remote
control unit will heat up too quickly
and turn the burner system off.

3.

Use the STATUS button on the hand-
held remote control unit to see the
operation mode being used and the
temperature setting selected. A red
light will come on beside the opera-
tion mode being used.

4.

To turn the burners off when oper-
ating in the manual mode, press the
OFF button. If operating in the auto
mode, press the MAN button, then
press the OFF button. The pilot will
remain lit.

IMPORTANT:

To turn the

pilot off, manually turn the gas con-
trol knob on the burner system to the
OFF position.

ON
OFF
REMOTE

LO HI

OFF

ON

PI

LO

T

Selector Switch in
Remote Position
(Optional Remote
Control)

Variable Control Knob

Gas Control Knob
in On Position