Cooking, Installation requirements, Utility – Viking DGCU105-4B User Manual
Page 4: Access requirements
DGCU105-4B
30”W. Four-Burner
Cooktop
DGCU165-5B
36”W. Five-Burner
Cooktop
DGCU155-6B
45”W. Six-Burner
Cooktop
Cutout opening
28-3/4”
(73.0 cm) min.
to
29-7/8”
(75.9 cm) max.
27”
(68.6 cm)
1-1/16”
(2.7 cm)
1-1/16”
(2.7 cm) 2-1/4”
(5.7 cm)
19-11/16”
(50.0 cm) min.
to
20-1/2”
(52.1 cm) max.
20-5/8”
(52.4 cm)
29-1/8”
(73.9 cm)
DGCU105-4B
DGCU165-5B
DGCU155-6B
Cutout width
28-3/4”(73.0 cm) min.
34-1/2” (87.6 cm) min.
42-7/8” (108.9 cm) min.
to 29-7/8” (75.9 cm) max.
to 35-7/8” (91.1 cm) max.
to 44-1/8” (112.1 cm) max.
Cutout height
2-3/4” (7.0 cm)*
Cutout depth
19-11/16” (50.0 cm) min. to 20-1/2” (52.1cm) max.
Surface burner rating
Left front
14,000 BTU Nat. (4.1 kW)/
12,000 BTU Nat. (3.5 kW)/
12,000 BTU Nat. (3.5 kW)/
13,500 BTU LP (4.0 kW)
11,500 BTU LP (2.8 kW)
11,500 BTU LP (2.8 kW)
Left rear
12,000 BTU Nat. (3.5 kW)/
10,000 BTU Nat./LP (2.9 kW)
8,000 BTU Nat./LP (2.1 kW)
11,500 BTU LP (2.8 kW)
Right front
6,000 BTU Nat./LP (1.8 kW)
6,000 BTU Nat./LP (1.8 kW)
8,000 BTU Nat./LP (2.1 kW)
Right rear
8,000 BTU Nat./LP (2.1 kW)
8,000 BTU Nat./LP (2.1 kW)
6,000 BTU Nat./LP (1.8 kW)
Center
14,000 BTU Nat. (4.1 kW)/
10,000 BTU Nat./LP (2.9 kW)
13,500 BTU LP (4.0 kW)
Right center
14,000 BTU Nat. (4.1 kW)/
13,500 BTU LP (4.0 kW)
*Top of grate support should be 1-1/8” (2.8 cm) above countertop. There must be a 1” (2.5 cm) clearance undercounter on all sides of the cooktops.
COOKING
Designer Built-In Gas
30”/36”/45”W. Ceramic Cooktop
P L A N N I N G A N D D E S I G N G U I D E
V I K I N G R A N G E . C O M • 1 - 8 8 8 - V I K I N G 1
R E L E A S E D 1 2 / 1 / 0 7
© 2 0 0 7 V R C — I N F O R M AT I O N S U B J E C T T O C H A N G E
UTILITY
REQUIREMENTS
GAS
• Must be ordered
from the factory
either natural gas or
LP/propane (DGCU
models are not field
convertible). Specify
LP after model
number and color
code, for example,
“DGCU155-6BSSLP”
• Accepts standard
residential 1/2”
(1.3 cm) ID gas
service line
• Gas manifold
pressure
• Natural gas 5.0”
W.C.P.
• LP/propane 10.0”
W.C.P.
ELECTRICAL
• 4-foot (121.9 cm)
cord included with
cooktop
• 3-wire with ground/
3-prong plug
• 120 V/60 Hz
• Max. amp usage—2.0
• *If electrical power is
not supplied or is
interrupted, the
open top burners
can be lit manually
with a match.
PLUMBING
Not applicable
Installation Requirements
ACCESS REQUIREMENTS
Cutout opening
34-1/2”
(87.6 cm) min.
to
35-7/8”
(91.1 cm) max.
33”
(83.8 cm)
15/16”
(2.4 cm)
15/16”
(2.4 cm)
2-1/4”
(5.7 cm)
20-5/8”
(52.4 cm)
19-11/16”
(50.0 cm) min.
to
20-1/2”
(52.1 cm) max.
34-7/8
(88.6 cm)
Cutout opening
42-7/8”
(108.9 cm) min.
to
44-1/8”
(112.1 cm) max.
42”
(106.7 cm)
7/16”
(1.1 cm)
7/16”
(1.1 cm)
2-1/4”
(5.7 cm)
20-5/8”
(52.4 cm)
19-11/16”
(50.0 cm) min.
to
20-1/2”
(52.1 cm) max.
42-7/8”
(108.9 cm)
30”W. Cutout
36”W. Cutout
30”W. Cutout
w/Downdraft
45”W. Cutout
36”W. Cutout
w/Downdraft
45”W. Cutout
w/Downdraft