Y
Picture is okay, but there is no
sound.
•
Audio output is muted.
•
Volume setting is too low.
•
Source component is
connected incorrectly or
not at all.
•
Press the MUTE button on
the remote control.
•
Turn up the volume.
•
Check audio connections to
source component.
Image is too bright and/or
lacks definition in the bright
areas of the image.
•
Contrast is set too high.
•
Lower the contrast setting.
Image appears “washed out”
and/or dark areas appear too
bright.
•
Brightness is set too high.
•
Lower the brightness
setting.
Colors in the image are
swapped; for example, reds
appear blue or vice versa.
•
Incorrect color space
setting.
•
The Pr, Y or Pb outputs from
the source to Input 4 on the
PlasmaView are incorrect.
•
Select the correct color
space (refer to Color Space
on page 40).
•
Ensure that the YPbPr
(component) source output
connections to Input 4 are
correct (see Figure 3-7).
RGB-HD images appear
“noisy.”
•
Frequency and Phase
settings need adjustment.
•
Manually adjust Frequency
and Phase settings, or
perform an Auto Setup
(refer to Screen on
page 38).
One of the following error
messages appears on-screen:
•
CAUTION
OUT OF RANGE
•
CAUTION
UNSUPPORTED SIGNAL
•
SIGNAL NG
•
The resolution and
frequency of the video card
in the computer are not
compatible with the
PlasmaView.
•
Select a compatible
resolution and vertical
frequency (refer to
Computer/Video Signal
Compatibility on page 69).
The image is too large or too
small.
•
Image size needs adjusting.
•
Adjust the image size (refer
to Screen on page 38).
One of the following error
messages appears on-screen:
•
WARNING
THERMAL ALERT
SHUT DOWN (**)
•
WARNING
FAN FAILURE
SHUT DOWN (**)
(“(**)” represents a two-digit
error code.)
•
Ambient temperature is too
high.
•
Cooling fan has
malfunctioned.
•
Turn off main power.
Remove any objects
blocking the cooling vents
on the PlasmaView and/or
clean the vents.
•
Immediately turn off
power, remove the power
plug from its outlet, and
consult your Vidikron
dealer.
Table 5-1. Troubleshooting Chart (continued)
Symptom
Possible Cause(s)
Solution