beautypg.com

Ventilation, Installation requirements, Built-in classic chimney glass wall hood – Viking DGWH User Manual

Page 4

background image

P L A N N I N G A N D D E S I G N G U I D E

V I K I N G R A N G E . C O M

1 - 8 8 8 - V I K I N G 1

R E V I S E D 1 / 1 5 / 0 9

© 2 0 0 9 V R C — INFORMATION SUBJECT TO CHANGE

Proper installation/ducting is extremely
important to ensure maximum
performance. Use a qualified and
trained installer.

DUCTING
• 450 CFM interior (blower

included)

• Check with a qualified and

trained installer for local codes
and makeup air requirements,
if any.

• Max. duct run length—50’

(152.4 m)
o Duct run length is for general

reference only; for longer
duct runs, increase duct size
and contact a qualified and
trained installer.

o Straight runs and gradual

turns are best; for example,
each 90” elbow is equivalent
to 5’ – 10’ (1.52 – 3.05 cm) of
straight run.

• 6” round duct

o Never use flexible duct; it

creates back pressure/air
turbulence and greatly
reduces performance.

GAS
Not applicable

ELECTRICAL
• Hardwire direct with two-wire

with ground

• 120 VAC/60 Hz
• Max. amp usage—3.13

PLUMBING
Not applicable

VENTILATION

Built-In Classic Chimney Glass Wall Hood

Installation Requirements

Model

Interior Ventilator Kits

Interior Duct Size

Interior Max. Amps

DGWH3646

450 CFM Standard

6” (15.2 cm)

3.13

Note: All CFMs are based on tests with 0.1 static pressure. Without applying static pressure (some brands do not), CFM could be greatly
overstated.

UTILITY REQUIREMENTS

DGWH Designer

Chimney Glass Wall Hood