Vector IVECO MOTOS V08 ENT M12 User Manual
Page 35

INSTALLATION DIRECTIVE
MAY 2006
V08 EnT M75 - M11 - M12
Clogged air filter sensor
Vacuum switch, providing the signal for the clogged air filter
alarm indicator.
Operating voltage:
from 6 to 24 V
Condition at ambient pressure
normally open
Closing vacuum:
≥ -52 mbar
Operating temperature:
-20 / +80 °C
Maximum current
0.1 A (not inductive)
Electrical poles
isolated
Clogged oil filter sensor
Differential pressure switch, providing the signal for the
related indicator when pressure difference between inlet /
outlet oil filter is more then a limit value.
Operating voltage:
from 6 to 24 V
Condition at ambient pressure
normally open
Closing pressure:
2.4 ± 0.3 bar
Opening pressure:
1.8 ± 0.3 bar
Maximum current
3 A (not inductive)
Electrical poles
isolated
Figure 0
Figure 1
Clogged fuel filter sensor
Figure 2
Pressure switch, providing the signal for the related indicator,
when the pressure at the fuel filter inlet is too high.
Operating voltage:
from 6 to 24 V
Condition at ambient pressure
normally closed
Opening pressure:
1.5 ± 0.1 bar
Maximum current
0.1 A (not inductive)
Electrical poles
isolated
Exhaust gas temperature sensor
niCr-ni thermocouple sensor with insulated poles, pro-
viding the signal for the analog indication of exhaust gas
temperature.
Temperature
Voltage
°C
mV
100
4.10
200
8.13
300
12.21
400
16.40
500
20.65
600
24.91
700
29.14
800
33.30
900
37.36
Figure
04_029_C
04_030_C
04_260_n
04_238_n