beautypg.com

Ventilation, Installation requirements, Built-in versavent™ rear downdraft – Viking VEDV User Manual

Page 4

background image

VIPR Professional

Downdraft

VIPR Professional

Downdraft w/Remote

DIPR Designer

Downdraft w/Remote

P L A N N I N G A N D D E S I G N G U I D E

V I K I N G R A N G E . C O M • 1 - 8 8 8 - V I K I N G 1

R E L E A S E D 1 2 / 1 / 0 7

© 2 0 0 7 V R C — INFORMATION SUBJECT TO CHANGE

VENTILATION

Built-In VersaVent™ Rear Downdraft

DUCTING
• Check with a qualified and

trained installer or local codes
for makeup air requirements,
if any.

• Max. duct run length (see

Installation Notes &
Accessories)

• For best performance, use the

shortest length of ductwork
and a minimum number of
elbows.

• The system will operate most

efficiently when the ductwork
does not exceed 40’ of
equivalent duct. For longer
duct runs, increase duct size
and contact a qualified and
trained installer.

• Straight runs and gradual

turns are best; for example,
each 90° elbow is equivalent
to 5’ – 10’ (152.4 – 304.8 cm)
of straight run.

o 6” or 10” round elbow= 6’

of straight duct

o 3-1/4” x 10” to 6” round

transition= 2’ of straight
duct

o 3-1/4” x 10” 90° elbow= 8’

of straight duct

• Never use flexible duct; it

creates back pressure/air
turbulence and greatly
reduces performance.

GAS
• Not applicable

ELECTRICAL
• 2’-long power cord with 3-

pronged plug included

• Internal blowers require a

grounded outlet within reach
of the power cord

• External blowers require direct

hardwiring with 2-wire with
ground, using locally-supplied
wire, and connected to the
downdraft plug (included)

• 120 VAC/60 Hz
• Max. amp usage (rating does

not include recommended
ventilator kit rating—See
Installation Notes &
Accessories)

PLUMBING
• Not applicable

Installation Requirements

UTILITY REQUIREMENTS

Model

Ventilator Kits

Duct Size

Max. Amps

Interior

Exterior

Interior

Exterior

Interior

Exterior

VIPR101

VIDV500

VEDV900

3–1/4” x 10” (8.3 x 25.4 cm)

10” (25.4 cm)

4.0

5.7

VIPR161

VIDV500

VEDV900

3–1/4” x 10” (8.3 x 25.4 cm)

10” (25.4 cm)

4.0

5.7

VIPR181

VIDV500

VEDV900/1200

3–1/4” x 10” (8.3 x 25.4 cm)

10” (25.4 cm)

4.0

5.7/3.0

VIPR101R

VIDV500

VEDV900

3–1/4” x 10” (8.3 x 25.4 cm)

10” (25.4 cm)

4.0

5.7

VIPR161R

VIDV500

VEDV900

3–1/4” x 10” (8.3 x 25.4 cm)

10” (25.4 cm)

4.0

5.7

VIPR181R

VIDV500

VEDV900/1200

3–1/4” x 10” (8.3 x 25.4 cm)

10” (25.4 cm)

4.0

5.7/3.0

DIPR100R

VIDV500

VEDV900

3–1/4” x 10” (8.3 x 25.4 cm)

10” (25.4 cm)

4.0

5.7

DIPR160R

VIDV500

VEDV900

3–1/4” x 10” (8.3 x 25.4 cm)

10” (25.4 cm)

4.0

5.7

DIPR150R

VIDV500

VEDV900

3–1/4” x 10” (8.3 x 25.4 cm)

10” (25.4 cm)

4.0

5.7

Note:

Proper installation/ ducting is extremely important to ensure maximum performance. Use a qualified and trained installer.