Terminal description (continued) – Vidikron 80 User Manual
Page 36
36
2-3. Parameters used for the data format
The following 3 types of parameters are used for command and response data:
1 Numeric value 2 ON/OFF 3 Special parameters
Each parameter is as follows:
1
Numeric
value
A 2-byte hexadecimal value (sign included) is represented by a set of 4-digit (4-byte) characters.
Assignable range: 8000H to 7FFFH
2
ON/OFF
Shows the status (ON or OFF) of the unit, such as POWER and HIDE.
Character
Hex
Meaning
0
30
OFF
1
31
ON
3
Special
Parameters
Parameters for input video-image format
Character
Hex
Meaning
0
30
60p
1
31
50p
Operation
mode
parameters
Character
Hex
Meaning
0000
30h 30h 30h 30h
Standby mode
0001
30h 30h 30h 31h
Power-on mode
0002
30h 30h 30h 32h
Cool down mode
0004
30h 30h 30h 34h
Emergency mode
3. External control command table
Function
Command
Asking
Data Type
Power On
ELSE
Numeric Value
ON / OFF
Special Data
Operate
U0F
X
X
X
O
X
MUTE
U00
O
X
X
O
X
Left/Right Reversal
U17
O
X
X
O
X
Top/Bottom Inversion
U18
O
X
X
O
X
Operation Mode
Z03
O
O
X
X
O
Operation mode: Only Asking command is possible
Terminal Description (continued)