Cooking, Installation requirements, Utility – Viking DECU165-5B 36"W User Manual
Page 4: Access requirements
Cutout opening
28-5/8”
(72.7 cm) min.
to
29-7/8”
(75.9 cm) max.
27”
(68.6 cm)
1-1/16”
(2.7 cm)
1-1/16”
(2.7 cm) 2-1/4”
(5.7 cm)
19-3/4”
(50.2 cm) min.
to
20-1/8”
(51.1 cm) max.
20-5/8”
(52.4 cm)
29-1/8”
(73.9 cm)
Cutout opening
34-3/4”
(88.3 cm) min.
to
35-7/8”
(91.1 cm) max.
33”
(83.8 cm)
15/16”
(2.4 cm)
15/16”
(2.4 cm)
2-1/4”
(5.7 cm)
20-5/8”
(52.4 cm)
19-3/4”
(50.2 cm) min.
to
20-1/8”
(51.1 cm) max.
34-7/8”
(88.6 cm)
Cutout opening
42-7/8”
(108.9 cm) min.
to
44-1/8”
(112.1 cm) max.
42”
(106.7 cm)
7/16”
(1.1 cm)
7/16”
(1.1 cm)
2-1/4”
(5.7 cm)
20-5/8”
(52.4 cm)
19-3/4”
(50.2 cm) min.
to
20-1/8”
(51.1 cm) max.
42-7/8”
(108.9 cm)
30”W. Cutout
36”W. Cutout
30”W. Cutout
w/Downdraft
45”W. Cutout
36”W. Cutout
w/Downdraft
45”W. Cutout
w/Downdraft
DECU106-4B
DECU166-5B
DECU156-6B
Cutout width
28-5/8” (72.7 cm) min.
34-3/4” (88.3 cm) min.
42-7/8” (108.9 cm) min.
29-7/8” (75.9 cm) max.
35-7/8” (91.9 cm) max.
44-1/8” (112.1 cm) max.
Cutout height
3-1/8” (7.9 cm) min.
With conduit
4-1/8” (10.5 cm)
Cutout depth
19-3/4” (50.2 cm) min. to 20-1/8” (51.1 cm) max.
Surface burner rating
240V
208V
240V
208V
240V
208V
Right front
1,500 watts
1,125 watts
1,500 watts
1,125 watts
1,500 watts
1,125 watts
Right rear (dual element)
2,500/1,000 watts/1,875/750 watts
2,200/
1,650/
2,200/
1,650 watts
1,000 watts
562 watts
950 watts
Center right
N/A
N/A
1,200 watts
900 watts
Center (dual element)
N/A
2,500/
1,875/
N/A
1,000 watts
750 watts
Center left (dual element)
N/A
N/A
2,500/
1,875/
1,000 watts
750 watts
Left front
1,800 watts
1,350 watts
1,800 watts
1,350 watts
1,800 watts
1,350 watts
Bridge
800 watts
600 watts
800 watts
600 watts
800 watts
600 watts
Left rear
1,800 watts
1,350 watts
1,800 watts
1,350 watts
1,800 watts
1,350 watts
DECU106-4B
30”W. Four-Element
Cooktop
DECU166-5B
36”W. Five-Element
Cooktop
DECU156-6B
45”W. Six-Element
Cooktop
COOKING
Designer Built-In Electric Radiant
30”/36”/45”W. Glass Ceramic Cooktop
P L A N N I N G A N D D E S I G N G U I D E
V I K I N G R A N G E . C O M
•
1 - 8 8 8 - V I K I N G 1
R E V I S E D 5 / 1 1 / 1 1
© 2 0 1 1 V R C — I N F O R M AT I O N S U B J E C T T O C H A N G E
UTILITY
REQUIREMENTS
GAS
• Not applicable
ELECTRICAL
• 4-foot (121.9 cm)
flexible conduit
included*
• 3-wire conduit with a
No. 10 ground wire
• 240 – 208/120 V/60 Hz
• Maximum amp
usage—(240V/208V)
o 4B—35.0/30.0
o 5B—44.0/34.0
o 6B—49.0/42.0
• Do not use an
extension cord with
this appliance.
PLUMBING
Not applicable
Installation Requirements
ACCESS REQUIREMENTS
Note: Before cutting countertop cutout, check the inside clearance available from the inside back wall to the proposed
placement of the cooktop. A minimum of 1-3/4” (4.4 cm) is required from the back wall of the cooktop to the inside wall of
the back cabinet. This may require a distance greater than the 0” minimum approved distance.