beautypg.com

Cooking, Installation requirements – Viking VDSC367-6B User Manual

Page 4

background image

2”

(5.1 cm)

Dia.

2-3/4”

(7.0 cm)

4-3/8”

(11.1 cm)

2-1/2”

(6.4 cm)

1-3/4”

(4.4 cm)

31-1/16”

(78.9 cm)

28-5/16”

(71.9 cm)

23-7/16”

(59.5 cm)

Gas or Electrical
connection in
this area

Gas connection
in this area

P L A N N I N G A N D D E S I G N G U I D E

V I K I N G R A N G E . C O M • 1 - 8 8 8 - V I K I N G 1

R E L E A S E D 1 2 / 1 / 0 7

© 2 0 0 7 V R C — I N F O R M AT I O N S U B J E C T T O C H A N G E

VGSC307-4B

VGSC367-6B

VGSC367-4G

VGSC367-4Q

Surface burner rating

Four grated burners (each)

15,000 BTU Nat. (4.4 kW)/

15,000 BTU Nat. (4.4 kW)/

15,000 BTU Nat. (4.4 kW)/

13,500 BTU LP (4.0 kW)

13,500 BTU LP (4.0 kW)

13,500 BTU LP (4.0 kW)

Six grated burners (each)

15,000 BTU Nat. (4.4 kW)/
13,500 BTU LP (4.0 kW)

One griddle

15,000 BTU Nat. (4.4 kW)/
13,500 BTU LP (4.0 kW)

One grill

18,000 BTU Nat. (5.3 kW)/

Preheat Rating

16,000 BTU LP (4.7 kW)

Preheat rating

240V—6,000 watts

240V—6,460 watts

240V—6,460 watts

240V—6,460 watts

208V—4,530 watts

208V—4,850 watts

208V—4,850 watts

208V—4,850 watts

Broil burner rating

Maxi-Broil—8-pass

240V—3,000 watts
208V—2,250 watts

Mini-Broil—4-pass

240V—1,250 watts

208V—940 watts

Bake burner rating

240V—2,935 watts

240V—3,440 watts

240V—3,440 watts

240V—3,440 watts

(partial power from broil element)

208V—2,247 watts

208V—2,620 watts

208V—2,620 watts

208V—2,620 watts

TruConvec rating

240V—2,200 watts

208V—1,650 watts

COOKING

Professional Freestanding Dual Fuel Self-Clean 30”/36”W.

Sealed Burner Range

Installation Requirements

ACCESS REQUIREMENTS

UTILITY

REQUIREMENTS

GAS
• Shipped natural gas standard; field

convert to LP/propane with optional
accessory kit or order as LP by
adding LP after color code

• Accepts standard residential 1/2" ID

gas service line

• Gas manifold pressure

o Natural gas 5.0" W.C.P.
o LP/Propane 10.0" W.C.P.

ELECTRICAL
• Electrical connection box on

product for hardwire direct; connect
with locally supplied, flexible cord

rated 40 amp; 125/250V min.; must
be agency-approved for use with
household electric ranges. It should
be fused separately.

• Check your national and local codes

regarding this unit.

• Maximum amp usage—

240 - 208/120 VAC/60 Hz
o 4B

240V—6098 watts; 25.4 amps

208V—4757 watts; 22.9 amps

o 6B

240V—6634 watts; 27.6 amps

208V—5163 watts; 24.8 amps

o 4G

240V—7462 watts; 31.1 amps

208V—5880 watts; 28.3 amps

o 4Q

240V—6634 watts; 27.6 amps

208V—5163 watts; 24.8 amps

PLUMBING
Not applicable

This manual is related to the following products: