beautypg.com

Cooking, Installation requirements – Viking VGSC388-4G User Manual

Page 4

background image

VGSC306-4B

30”W. Four-Burner

Range

VGSC366-6B

36”W. Six-Burner

Range

VGSC366-4G

36”W. Four-Burner/

Griddle Range

VGSC366-4Q

36”W. Four-Burner/

Grill Range

VGSC306-4B

VGSC366-6B

VGSC366-4G

VGSC366-4Q

Surface burner rating

Four grated burners (each)

15,000 BTU Nat. (4.4 kW)/

15,000 BTU Nat. (4.4 kW)/

15,000 BTU Nat. (4.4 kW)/

13,500 BTU LP (4.0 kW)

13,500 BTU LP (4.0 kW)

13,500 BTU LP (4.0 kW)

Six grated burners (each)

15,000 BTU Nat. (4.4 kW)/
13,500 BTU LP (4.0 kW)

One griddle

15,000 BTU Nat. (4.4 kW)/
13,500 BTU LP (4.0 kW)

One grill

18,000 BTU Nat. (5.3 kW)/
16,000 BTU LP (4.7 kW

Broil burner rating

18,000 BTU Nat. (5.3 kW)/16,000 BTU LP (4.7 kW)

Bake burner rating

30,000 BTU Nat./LP (8.8 kW)

2”

(5.1 cm)

Dia.

2-3/4”

(7.0 cm)

4-3/8”

(11.1 cm)

2-1/2”

(6.4 cm)

1-3/4”

(4.4 cm)

31-1/16”

(78.9 cm)

28-5/16”

(71.9 cm)

23-7/16”

(59.5 cm)

Gas or Electrical
connection in
this area

Gas connection
in this area

COOKING

Professional Freestanding Gas Self-Clean 30”/36”W.

Open Burner Range

P L A N N I N G A N D D E S I G N G U I D E

V I K I N G R A N G E . C O M • 1 - 8 8 8 - V I K I N G 1

R E L E A S E D 1 2 / 1 / 0 7

© 2 0 0 7 V R C — I N F O R M AT I O N S U B J E C T T O C H A N G E

UTILITY

REQUIREMENTS

GAS
• Shipped natural

gas standard;
field convert to
LP/propane with
optional accessory
kit or order as LP
by adding LP after
color code

• Accepts standard

residential 1/2” ID
gas service line

• Gas manifold

pressure
o Natural gas 5.0”

W.C.P.

o LP/Propane

10.0” W.C.P..

ELECTRICAL
• Four-foot (121.9

cm) cord included
with range

• Three-wire with

ground/three-
prong plug

• 120 V/60 Hz
• Maximum amp

usage—
o 30”W. 4B—2.3
o 6B—2.3
o 4G—6.0
o 4Q—2.4

PLUMBING
Not applicable

Installation Requirements

ACCESS REQUIREMENTS

Note: If the gas supply is installed through the rear wall, the location MUST be 31-1/16” (78.9 cm) above
the floor and 2-3/4” (7.0 cm) from the left hand side (when facing the unit) or within a maximum of
4-3/8” (11.1 cm) above the floor as specified in the drawing above.

This manual is related to the following products: