Moisture collects on

Hot and humid conditions.

Extremely hot and humid conditions can cause

outside surface of cabinet

condensation on the outside of unit. As
humidity and/or temperature decreases,
condensation will disappear

Moisture collects inside

Too many door openings.

Limit the amount of door openings.

of the unit.

Prolonged door openings

Limit the amount of time door is open.

Hot and humid conditions.

Extreme hot and humid conditions. Move unit
to a controlled environment. May consider
having the defrost section changed from 12 to
6 hours.

Defrost thermistor out of specification. Consult dealer or servicer for diagnosis.

The unit is too warm or

Adjustment of the temperature

Adjust the temperature control to a warmer or

too cold.

control knob.

colder setting and allow 24 hours before
readjusting if necessary.

Temperature control side in the

Adjust temperature control slide as necessary

refrigerator section too far open.

in the refrigerator section of the unit.

The unit is warm inside with

Drip tray heater is on.

The drip tray heater will remain energized with

the temperature control knob

the control knob in the off position. Unplug

in the “OFF” position.

the unit if storing or leaving the unit for
extended periods of time.

Items on door shelf

The upper two shelves of the door

Turn the temperature control knob to a lower

sometimes freeze.

freeze under warm conditions.

number or move the items to the refrigerator
section.

P

Prro

ob

blle

em

m

P

Po

ossssiib

blle

e C

Caau

usse

e

S

So

ollu

uttiio

on

n

TROUBLESHOOTING CHART

DIAGNOSTIC LED

In the back in the grille, there is a diagnostic/status LED. This LED is used to help diagnosis any problem with the unit
and to tell its status.

LLE

ED

D S

Sttaattu

uss

C

Co

od

de

e//P

Prro

ob

blle

em

m

Not on or blinking

Unit does not have power

Steadily blinking once per second

Unit temperature control is in the “OFF” position

Continuously on

Unit is “ON” and operating correctly

2 blinks and pause; repeated pattern

Defrost thermistor out of range

3 blinks and pause; repeated pattern

Evaporator normal cycling thermistor out of range

4 blinks and pause; repeated pattern

Control potentiometer out of range

2 blinks, pause, 3 blinks, pause; repeated pattern

Both defrost and evaporator thermistor out of range