Utica Gas-fired Boiler User Manual
Page 27

§
§
§ **
†
∆∆∆∆∆
Natural
Propane
Boiler
A.G.A.
Heating
I=B=R
NetRating
No.
Recommended
Gas
Orifice
Water
No.
Input
Capacity NetOutput Sq. Ft. HW
of
Air Cushion
Orifice
Drill
Content
Btu/Hr.
Btu/Hr.
Btu/Hr
@ 170
o
Burners
Tank
Drill Size
Size
(Gals.)
MGB 50
50,000
42,000
37,000
243
1
15
30
47
2.4
MGB 75
75,000
63,000
55,000
365
2
15
33
50
4.0
MGB 100 100,000
83,000
72,000
481
2
30
30
47
4.0
MGB 125 125,000 104,000
90,000
603
3
30
31
49
5.6
MGB 150 150,000 124,000
108,000
719
3
30
30
47
5.6
MGB 175 175,000 143,000
124,000
829
4
30
31
49
7.2
MGB 200 200,000 165,000
143,000
957
4
30
30
47
7.2
MGB 250 250,000 205,000
178,000
1189
5
30
30
47
8.8
MGB 300 299,999 243,000
214,000
1368
6
60
30
47
10.4
RA
RA
RA
RA
RATINGS
TINGS
TINGS
TINGS
TINGS AND D
AND D
AND D
AND D
AND DA
A
A
A
AT
T
T
T
TA
A
A
A
A
N
N
N
N
NA
A
A
A
ATURAL GAS
TURAL GAS
TURAL GAS
TURAL GAS
TURAL GAS AND PR
AND PR
AND PR
AND PR
AND PROP
OP
OP
OP
OPANE GAS
ANE GAS
ANE GAS
ANE GAS
ANE GAS
STANDARD EQUIPMENT: Boiler Jacket, Cast Iron Boiler Battery, Combination Aquastat Relay, Theraltimeter
Gauge,Circulator with return piping to boiler, Main Gas Burners, Combination 24 Volt Gas Control (includes
automatic gas valve, gas pressure regulator, automatic pilot, safety shutoff, pilot flow adjustment, pilotfilter),
A.S.M.E. Relief Valve, Drain Cock, Spill Switch, Rollout Switch, Automatic Vent damper. Not shown are
a wiring harness, thermocouple, and non-linting safety pilot.
OPTIONAL EQUIPMENT: Intermittent Electric Ignition Pilot System.
EXPLANATORY NOTES
--All boilers are design certified for installation on noncombustible floor.
--For installation on combustible floors use combustible floor kit.
--Recommended chimney height 20 feet. In special cases where conditions permit, chimney height may
be reduced to 10 feet. Refer to the latest revision of NFGC part 11.
--Electric service to be 120 Volts, 15 Amps, 60 Hz.
--The MEA number for the MGB series boiler is 19-79 Vol. II
§ For elevations above 2000 feet, ratings should be reduced at a rate of 4% for each 1000 feet above sea
level.
∆∆∆∆∆ Tank sized for non-ferrous baseboard or radiant panel systems. Increase size for cast iron baseboard
and radiation.
† Base on 170' temperature in radiators.
--Net I=B=R ratings include 15% allowance for normal piping and pick-up load. Manufacturer should be
consulted on installations having otherthan normal piping and pick-up requirements.
**For equivalent square feet of radiation, divide I=B=R output by 150.
PAGE 26