Uniden BCD996T User Manual
Page 77

77
Programming Your Scanner
MS1: Motorola 800 MHz Type I Standard
MS2: Motorola 800 MHz Type II Standard
MP1: Motorola 800 MHz Type I Splinter
MP2: Motorola 800 MHz Type II Splinter
P25: APCO 25 (all bands)
M92: Motorola 900 MHz
MV2: Motorola VHF
MU2: Motorola UHF
EDW: EDACS Wide
EDN: EDACS Narrow
Follow these steps to change the system name.
[MENU]
Program System
F
Select a trunked system
F
Edit Site
F
Select a Site
F
Edit Name
F
To enter a letter, turn the Scroll Control until the character you want appears. To
enter a decimal point, press [.No]. To move the cursor to the left, press [4]. To
move the cursor to the right, press [6].
To clear a character, press [.No] twice. To clear all characters, press [.No] 3 times.
To accept an entry, press [E
YES
] or
F
.
[MENU]
Program System
F
Select a trunked system
F
Edit Site
F
Select a Site
F
Set Quick Key
F
After selecting this option, select any number from 0-99 to assign the system to a
quick key or press [.No] to assign the system to no quick key, then press
F
.
Setting the Site Quick Key
MESL