beautypg.com

User’s manual – U-Line ICE-MAKER/REFRIGERATOR User Manual

Page 30

background image

Problem

Possible Cause

Remedy

The unit is not

For model 29AD only:

cold enough

is the defrost timer set

(continued)

to the correct time of day?
See INITIAL START-UP

The unit is not cold The door was left open

Turn off the unit to manually

enough (Frost free

causing the evaporator

defrost the evaporator.

units only)

behind the back wall to

See DEFROSTING.

fill with frost preventing
proper air flow and cooling.

The unit frosts

Unit is manual

Models BI-15, 95, 98,

up

defrost model

and Combo 29A and
75A are manual defrost.
Refer to DEFROSTING

Door gasket not

Adjust door. See

sealing properly

ALIGNING THE DOOR

High ambient

Defrost unit manually.

temperatures or

See DEFROSTING

humidity

Water is leaking

Water supply

Tighten fitting. See

out the back

connection leaking

CONNECTING THE

of the unit

WATER SUPPLY

Ice cubes

Door gasket not

Adjust door. See

sticking together

sealing properly

ALIGNING THE DOOR

Infrequent use of cubes

Break apart cubes

Noise during

Copper water supply

Carefully bend tubing

operation

tubing contacting

away from cabinet and

internal components

components

Fan blade touching

Remove obstruction

obstruction (wiring,
foam insulation, etc.)

No ice

Bin arm locked in

Lower bin arm

upright position

Not enough ice

Control set too cold

Adjust control to a
warmer setting
(COUNTER-CLOCKWISE)

Ice cube size too

Set cube size smaller.

large

See ADJUSTING ICE
CUBE SIZE

Water leaks into

Water level set too

Set cube size smaller.

ice bucket

high

See ADJUSTING ICE
CUBE SIZE

Fresh food section

Ice bucket not fully

Push ice bucket

on Combo units

inserted

into place

too cold

Temperature control

Set control to warmer

set too cold

setting (COUNTER-
CLOCKWISE)

28