8. Leave water supply line and power cord disconnected until ready

to reuse.

NOTE

The use of anti-freeze or other products of this nature is not
necessary and is not recommended.

TROUBLESHOOTING

BEFORE CALLING FOR SERVICE

If the unit appears to be malfunctioning, read through NORMAL OPER-
ATION first. If the problem persists, check the TROUBLESHOOTING
GUIDE. Locate the problem in the guide and refer to the cause and its
remedy before calling for service. The problem could be something very
simple which can be solved without a service call.

TROUBLESHOOTING GUIDE

NEVER attempt to repair or perform maintenance on the
unit until the main electrical power has been disconnected.

Troubleshooting — What to check when problems occur

Problem

Possible Cause

Remedy

No interior light

Loose or burned out

Tighten or replace bulb

bulb

The unit is not

Light staying on

Adjust door so light switch

cold enough

bracket contacts switch
plunger. See ALIGNING
THE DOOR

Door gasket not

Adjust door. See

sealing properly

ALIGNING THE DOOR

Dirty condenser coils

Clean condenser. See
CARE AND CLEANING

Airflow to front grill

Airflow must not be

blocked

obstructed to front grill.
See INSTALLATION

Temperature not set

Turn control knob

cold enough

CLOCKWISE to set
temperature colder.
Allow 24 hours for
temperature to stabilize

!

WARNING

27