CLR2160, CLRCO2175

21

To check and test hose connections:

1. Make certain the unit is not plugged into an electrical

outlet.

2. Carefully push the power cord grommet through the

hole in the back panel (see Figure 36).

Figure 36

3. Remove 12 screws and back panel.

WARNING

Back panel serves as a guard. DO NOT put your
hands inside the ice maker cabinet or attempt to
touch any components except the discharge tube
during testing. Failure to follow this warning
could result in serious personal injury or death.

4. Check that the clamps and hose connections are tight at

the following areas (see Figure 37):

• Discharge tube (A)

• Drain tube (B)

• Vent tube (C)

Figure 37

5. Place a suitable container beneath the pump’s discharge

tube. (The bucket must be able to hold a minimum of
one gallon.)

6. Plug the ice maker power cord into a properly

grounded, polarized electrical outlet.

7. Verify pump operation by pouring one gallon of water

into the ice storage bin of the ice maker. The pump
should energize and pump the water into the container.

8. At this time, verify that all tube and clamp connections

are tight and leak free.

9. Unplug unit power cord from electrical outlet.

10. Reinstall back panel.

To connect to drain:

1. Attach the 5/8-inch ID drain connection on the back of

the unit to a 5/8-inch OD rigid tube, using a worm
clamp.

2. Attach the other end of the rigid tube to your 5/8-inch

ID drain line with a worm clamp.

3. Insulate the drain line, if necessary to prevent

condensation. Go on to Water Supply Connection.

Locally-Installed Drain Pump

If a gravity drain connection is not possible, and you have
not purchased the CLRCO2175 with factory-installed
pump, we strongly recommend the use of the U-Line P60
drain pump. The U-Line P60 drain pump is available
through your Dealer, or direct from U-Line with complete
installation instructions. If a pump other than the U-Line
P60 drain pump is to be used, it must meet the following
specifications:

• It must be UL listed and have a UL listed, 120 VAC,

3-wire grounded power cord.

• It must have overall maximum outside dimensions of

8-3/4" wide x 5-3/4" deep x 7-3/4" high.

• It must have a minimum flow rate of 1.5 gallons per

minute at 10 feet of lift.

• It must have a sealed sump which does not allow water

leakage in the case of a power outage, restricted drain
or pump failure.

• It must have a check valve in the discharge line to

prevent waste water return to the pump.

• It must have an overflow protection control which will

shut off power to the ice maker in the event of a pump
failure.

• It must have an operating temperature range of 50°F

to 110°F (10°C to 40°C).