U-Line CLRCO2175 User Manual
Page 16
16
CLR2160, CLRCO2175
Figure 20
3. Turn the door upside down and inspect the hinge plate
mounting holes.
• Your plate has slotted mounting holes (Figure
20, 1). Loosen but do not remove the two hinge
plate screws.
4. If door edge opposite the hinges needs to move up,
move plate toward outside of door (Figure 20, 2). If
door edge needs to move down, move plate toward
inside of door (Figure 20, 3). Repeat until top edge of
door is parallel with top of cabinet and tighten screws
securely (Figure 20, 1).
Figure 21
5. After adjustment is complete, remove the door closers
from the bottom hinge, clean thoroughly and apply
petroleum jelly to the mating surfaces of the closers. Be
sure that bosses on closers (Figure 21, 1) align with
holes in the door and bottom cabinet hinge plates.
Mount door and install top hinge pivot pin.
Door Reversal
Figure 22
Black and white units may be left- or right-hand opening.
Stainless steel unit doors cannot be reversed. The doors
are easily reversed by moving the hinge hardware to the
opposite side. The top hinge hardware will be used on the
bottom of the other side and the bottom hinge hardware
will be used on the top of the other side (Figure 22).
To reverse the door:
Figure 23
1. Remove top hinge screw pin (Figure 23, 1) from door
using a Phillips screwdriver. Remove door by tilting
forward and lifting off bottom hinge pin.
ULIN_0201_A
1
2
3
1
ULIN_0004_A
ULIN_0015_A
1
2
ULIN_0003_A