OM/SM-HY-6G(CE)
6
4.0 - Installation, Start-Up and Conversion
WARNING
THE UNIT MUST BE INSTALLED BY PERSONNEL WHO ARE QUALIFIED TO WORK WITH ELECTRICITY AND
PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE
EQUIPMENT. THE UNIT MUST BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES.
CAUTION
DO NOT INSTALL THE UNIT WITH THE RIGHT SIDE VENTS BLOCKED OR WITHIN 30 CENTIMETERS OF
A HEAT SOURCE (SUCH AS A BRAISING PAN, DEEP FRYER, CHAR BROILER, OR KETTLE).
TO AVOID DRAINAGE PROBLEMS, LEVEL THE UNIT FRONT TO BACK, OR PITCH IT SLIGHTLY TO THE
REAR.
4.1 General
4.1.1
Model Number and Dimensions
MODEL
WIDTH
mm (in.)
DEPTH
mm (in,)
HEIGHT
mm (in.)
WEIGHT
Kg (lbs)
HY-6G(CE)
549
(21.6)
894
(35.2)
1464
(57.6)
193
(425)
4.1.2
Siting and Clearances
The HY-6G(CE) steamer is suitable for installation in
combustible and noncombustible locations.
Minimum clearances for installation are:
Right Side
300 mm (12 inches)
Left Side
0 mm (0 inches)
Rear of Flue
150 mm (6 inches)
However, for easy service at least
300 mm (12
inches) clearance is required for the right side of
the unit, and it may
not be installed within 300 mm
(12 inches) of a heat source, as stated in the
Caution above.
The unit must be installed in a well-ventilated room
with an adequate air supply. The steamer must be
installed beneath a ventilation hood, since gas
combustion products exit the appliance.
Any item which might obstruct or restrict the flow of
air for combustion and ventilation must be removed.
Do not obstruct the flue cover or any front, side, rear,
or top vents after installation.
The area directly around the appliance must be
cleared of all combustible material. The installation
must conform with local codes or, in the absence of
local codes, with the National Fuel Gas Code, ANSI
Z223.1, latest edition, including the following:
The unit and its individual shutoff valve must be
disconnected from the gas supply system during
any pressure testing of that system at test pressures
in excess of ½ PSI (3.45 kPa). It must be isolated
from the gas supply piping system by closing its
individual manual shutoff valve during any pressure
testing of the gas supply piping system at test
pressures
equal to or less than ½ PSI (3.45 kPa).
4.2 Electrical Supply Connection
The unit is designed for connection to fixed wiring. A
suitably rated isolating switch with contact separation
of at least 3 mm on both poles must be fitted to the
installation. Wiring must be executed in accordance
with the regulations listed on page 2 of this manual.
Cable entry is at the bottom rear right side of the
appliance. To gain access the panel must be
removed. Open the lower front panel by removing its
screws. Lift the panel and swing its bottom toward
you. Set the panel aside.
Provide 230 Volt, 50 Hz, Single Phase, 15 Ampere
service. Maximum load is 2½ amps. The electrical
schematic is located in the service compartment. A
copy is also printed at the rear of this manual.
CAUTION
THE UNIT MUST HAVE A SEPARATE EARTHING
WIRE FOR SAFE OPERATION.
4.3 Gas Supply Connection
Incoming service must be of sufficient size to supply
full rate without excessive pressure drop. A gas
meter is connected to the service pipe by the Gas
Supplier. Any existing meter should be checked out
by the Gas Supplier to ensure that it has adequate
capacity to provide the required rate of gas to the
steamer, in addition to any other equipment.