6. Install spring onto brass roller, then place square
plate over spring.
7. Apply Locktite 242 to Keps nut and install Keps nut.
8. Install spring support pin, then push the retaining ring
onto the pin using a screwdriver.
9. Hold door spring open with a screwdriver or similar
tool, hold door handle in the down position and install
the U-channel, top end first - then lower channel into
position. Check that spring opens when door handle
is pushed up.
10. Apply Locktite 242 to U-channel mounting screws,
then install the screws.
11. Replace the two screws in the U-channel, applying
Locktite 242 to secure them in place.
10.30
Door Locking Pin
P/N 078914
Lock Nut
P/N 003823
1. Turn steamer off and allow it to cool.
2. Note and record the distance between the lock nut
and the end of the (bullet shaped) door locking pin.
This information is important and will be needed for
installation.
3. Loosen lock nut and remove lock nut and door pin
(bullet) from front panel.
4. To install new door locking pin, coat locking pin
threads with NEVER-SEEZ high temperature
compound.
5. Install locking pin and lock nut. The lock nut to end-
of-bullet distance should be approximately the same
as measured above, in Step 2.
10.31
Indicator Neons (Lockout)
1. Turn off main gas supply
2. Turn off oven power and disconnect from branch
circuit power.
3. Remove upper right side panel
4. Replace neons as necessary.