Om/sm-hy-6g(ce), 0 - service procedures – Unified Brands HYPERSTEAM HY-6G(CE) User Manual
Page 23

OM/SM-HY-6G(CE)
OM/SM-HY-6G(CE)
23
10.0 - Service Procedures
The following procedures are based upon having access to the steamer on all four sides. If the steamer is installed
between other appliances and there is not enough room on the sides for access, the steamer must then be pulled out
from its position to gain proper access.
Care should be taken in moving the steamer so as not to stress or pull on the electrical and water connections.
10.1
Top Right Side Panel (Louvered) - Removal
P/N 123183
1. With a flat blade screw driver remove the two 10-32
screws on the lower edge and one screw on the top
edge of the panel. The panel is held to the steamer
by two spring-like clips at the rear and bottom edge.
2. Once the screws are removed SLIDE the panel
towards the front with a lifting motion. Do not attempt
to PRY the panel. Once the panel is free of the rear
and lower clips, it may be lifted off.
ASSEMBLY TIP: When replacing the panel, press the
rear edge inward so that both clips will be retained by the
back flange. Make sure that the holes in the panel are in
alignment with the tapped holes in the steamer so that
the replacement of the two 10-32 screws will be easy and
not damage the screws.
10.2
Steamer Table Panels
Front P/N 096720
Rear P/N 096785
Left/Right Side P/N 096848
1. To remove the steamer table lower panel, simply
raise the panel and swing out. There are no fasteners
on this panels and it is retained only by upper and
lower tracks.
2. To remove the front and side panels remove the
screw(s) holding the panel, then remove the panels.
3. The front and rear panels are unique and the two
side panels are identical and interchangeable.
10.3
Left Side - Removal
P/N 123184
Under normal conditions, the left side cover should never
have to be removed as there are no operational and/or
replacement parts to be accessed. The single exception
is if the door has been reversed so that the handle is on
the LEFT and the Door Interlock Switch is found to be
defective and must be replaced. The door switches for
BOTH door positions are installed at the time of
manufacture, so there is no need to access the switch if
the door is to be reversed.
1. If the top/left side cover must be removed due to a
faulty door switch, remove the right side panel (as
above) first. Then remove the top left panel in the
same manner.
10.4
Adjustable Legs
P/N 042505
1. Each leg is provided with a screw type support post.
These may be extended or retracted by turning them
with a wrench or ChannelLock. Make sure that all
four legs are in tight contact with the floor for proper
steamer support.
2. If damaged, these posts may be replaced by tapping
out (on opposite sides of the leg) the threaded fitting
which is friction held in each stainless steel leg. The
stainless leg and the threaded fitting are one
assembly.
NOTE: The following components and assemblies are to
be found in the lower table portion of the steamer.
10.5
Steam Generator Drain Valve
P/N 071234
1. Turn off power and allow steamer to drain
completely. Remove back cover panel and loosen
hose clamps.
2. Disconnect both ends of the drain hose from the
spray box and the steam generator.
3. Unplug and disconnect the valve electrical wires.
Remove the nuts holding the valve to the plate.
Remove the valve from the threaded studs. Then
remove the silicone hose from the valve.
4. Inspect the silicone hose for any damage or lime
buildup. Replace hose if required.
5. Attach new drain valve to valve bracket. Pull silicone
hose through drain valve and loosely install hose
clamps over both ends of the hose. Be sure silicone
hose is properly aligned and does not have any
kinks, bends and/or twists.