Specifications – Toshiba CGSV90CC3 User Manual
Page 39
(6/16)
D4153497A
6. Specifications
[Electrical specification]
(1) Imager
all-pixel-data-readout interline transfer CCD
CSGV90CC3
CSGX36CC3
CSGS20CC2
CSGU15CC18
Number of total pixels
(H) x (V)
692 x 504
1077 x 788
1434 x 1050
1688 x 1248
Number of effective pixels
(H) x (V)
659 x 494
1034 x 779
1392 x 1040
1628 x 1236
Number of Video out pixels
(H) x (V)
640 x 480
1024 x 768
1280 x 960
1600 x 1200
Scanning area
(H) x (V)
4.88 x 3.66mm
2
(1/3 type)
4.81 x 3.62mm
2
(1/3 type)
6.47 x 4.84mm
2
(1/2 type)
7.16 x 5.44mm
2
(1/1.8 type)
Pixel size
(H) x (V)
7.4 x 7.4µm
2
4.65
x
4.65µm
2
4.65
x
4.65µm
2
4.40
x
4.40µm
2
Color filter
RGB primary color mosaic-on-tip color filter
(2) Scan method
Non-interlace
(3) Synchronization method
Internal synchronization
(4) Aspect ratio
4: 3
(5) Sensitivity
CSGV90CC3
CSGX36CC3
CSGS20CC2
CSGU15CC18
Standard subject
illuminance
1700 lx
F5.6
5000K
1/90s
2400 lx
F5.6
5000K
1/36s
1400 lx
F5.6
5000K
1/20s
1000 lx
F8
5000K
1/15s
(6) Minimum subject illuminance
F1.4, GAIN Maximum, video level 50 %, Gamma ON
CSGV90CC3
CSGX36CC3
CSGS20CC2
CSGU15CC18
Minimum subject
illuminance
20 lx
27 lx
18 lx
7 lx
(7) Gain
AGC/Manual switching (initial factory setting :Manual)
- AGC (Auto Gain Control)
Effective range
0 to +6dB
Effective area
Full screen
* When the random shutter is active, AGC function is disabled.
* When Raw output mode (8/10bit), AGC function is disabled.
- Manual setting
Setting range
0 to +6 dB (46 step, initial factory setting: 0 dB)
(8) Gamma correction
ON(Gamma = 0.65) /OFF(Gamma = 1.0) switching
initial factory setting: ON
* When Raw output mode(8/10bit),
Gamma correction function is disabled (OFF fixed).