beautypg.com

Roubleshooting, Uide – Top Innovations SF-226 User Manual

Page 13

background image

13

Top Innovations, Inc.

T

ROUBLESHOOTING

G

UIDE

PROBLEM

POSSIBLE CAUSE

SOLUTION

Unit fails to heat up. Heating

Indicator Light DOES NOT

illuminate.

Unit is not plugged in.

Plug power cord into electrical

outlet.

Unit is damaged or otherwise in

need of repair.

Immediately cease usage and

unplug. Contact Customer

Support for further assistance (see

Page 14 for details).

Household circuit breaker / ground

fault interrupter has tripped or

blown a fuse.

Reset circuit breaker / ground fault

interrupter, or replace fuse. If you

need assistance, contact a licensed

electrician.

Unit fails to heat up. Heating

Indicator Light DOES illuminate.

Boiler is empty.

Refer to Filling Boiler with

Water procedure on Page 10 for

refilling instructions.

Unit is damaged or otherwise in

need of repair.

Immediately cease usage and

unplug. Contact Customer

Support for further assistance (see

Page 14 for details).

Mineral build-up in unit.

Refer to Removing Mineral

Build-Up procedure on Page 12

for cleaning instructions.

Steam output is weak or

intermittent.

Water level in Boiler is running

low.

Refer to Filling Boiler with

Water procedure on Page 10 for

refilling instructions.

Mineral build-up in unit.

Refer to Removing Mineral

Build-Up procedure on Page 12

for cleaning instructions.