Perreaux SILHOUETTE SXV1 User Manual
Page 13
13
Capacitance
Loading
Table
Use this table to match the capacitance loading characteristics of
your SXV1 to that recommended by your cartridge manufacturer,
where switch in UP position is OFF and switch in DOWN
position is ON. Consult your cartridge documentation for the
correct capacitance figure.
C Load
Dip Switch Setting
(pF)
6
7
8
9
27
UP
UP
UP
UP
54
DOWN
UP
UP
UP
74
UP
DOWN
UP
UP
101
DOWN
DOWN
UP
UP
297
UP
UP
DOWN
UP
324
DOWN
UP
DOWN
UP
344
UP
DOWN
DOWN
UP
371
DOWN
DOWN
DOWN
UP
417
UP
UP
UP
DOWN
444
DOWN
UP
UP
DOWN
464
UP
DOWN
UP
DOWN
491
DOWN
DOWN
UP
DOWN
687
UP
UP
DOWN
DOWN
714
DOWN
UP
DOWN
DOWN
734
UP
DOWN
DOWN
DOWN
761
DOWN
DOWN
DOWN
DOWN
Gain Setting
Table
Use this table to configure the gain characteristics of your SXV1
to suit the output voltage of the cartridge you are using, where
switch in UP position is OFF and switch in DOWN position is
ON.
Consult your cartridge documentation for it’s rated output
voltage. Set the gain configuration where the “Sensitivity” of
your SXV1 is within ±25% of your cartridge output voltage. If
no configuration falls into this bracket, use the setting with the
sensitivity higher than your cartridge output voltage.
Gain
Sensitivity S/N Ratio THD+N
Dip Switch Setting
(dB)
(mV)
(dB)
(%)
10
11
12
40
7.57
81.9
0.010
UP
UP
UP
50
2.36
74.6
0.022 DOWN
UP
UP
59
0.81
64.0
0.058
UP
DOWN
UP
61
0.66
62.6
0.067 DOWN
DOWN
UP
70
0.23
55.4
0.122
UP
UP
DOWN
71
0.22
55.1
0.188 DOWN
UP
DOWN
72
0.18
54.6
0.199
UP
DOWN
DOWN
73
0.17
53.4
0.203 DOWN
DOWN
DOWN