Perreaux SILHOUETTE SXV1 User Manual
Page 14
14
Note: If more than one setting falls within ±25% of your cartridge
output voltage, the lower sensitivity configuration will
result in greater dynamic range, the higher will be less
susceptible to clipping.
Note: Rated output is 0.75V
RMS
.
Sensitivity value measured at rated output.
Gain measured at 1kHz.
Configuration
Example
Please use the following example of the popular Ortofon
Kontrapunkt b (Moving Coil) cartridge as a guideline.
Ortofon Kontrapunkt b specifications
Recommended load resistance:
50
Ω
-200
Ω
Recommended load capacitance:
not stated
Rated output voltage:
470µV
SXV1 configuration
Resistance loading:
89.7
Ω
Capacitance loading:
27pF
(if no capacitance loading is recommended, use the lowest value)
Gain:
61dB
(based on Sensitivity bracket of 470ìV±25%
⇒ 352.5µV-587.5µV)
DIP Switch Setting (left channel)
1 2 3 4 5 6 7 8 9 10 11 12
D D D D U U U U U D D U
Note: D = switch in DOWN position, U = switch in UP position
Note: The right and left DIP switches are a mirror image of each
other.