11-27

11. PROGRAMMING PROCEDURES

2.

When the ENTER key is pressed, bar code format is checked. An error occurs in the
following cases.

1

Check digit (C/D) is at other than digit-13.

2

Price check digit (PC/D) cannot be calculated. (Price is other than 4 or 5 digits.)

3

Price is not set serially beginning from P1 (P1 to P4, or P1 to P5).

4

Weight is not set serially beginning from W1 (W1 to W5).

3.

The usable keys to set the column are as follows:

EM1-31064

11.16 BAR CODE FORMAT

PLU #

1 2 3 4 5 6

Display

H H H H H H

1 2 3 4 5 6

FLAG

0

~

9

PLU #

1

~

6

UPC#

1

~

6

PC/D

1

PRICE

1

~

7

WEIGHT

1

~

6

C/D

1

4.

Digits and display of PLU#

5.

Digits and display of UPC#

6.

Digits and display of price

UPC #

1 2 3 4 5 6

Display

C C C C C C

1 2 3 4 5 6

7.

Display of weight digits

8.

Setting Items

Price $

1 2 . 3 4

Display

P P

P P

1 2

3 4

$

1 2 3 . 4 5

P P P

P P

1 2 3

4 5

Weight

1 2 . 3 4 5

lb

Display

W W

W W W

1 2

3 4 5

Weight

1 2 . 3 4 5

kg

Display

W W

W W W

1 2

3 4 5

Flag

PLU#

UPC#

PC/D

C/D

Weight

Price

1

2

3

4

5

6

7