Toshiba 3006GAL User Manual
Page 33

Toshiba Corporation Digital Media Network Company
Page 33 of 157
© 2005, Copyright TOSHIBA Corporation All Rights Reserved
10.3.3 Signal Treatment
Driver types and requirements for the signal pull- up and down are as follows. Resistor requirement is minimum for the
host. - IO16 is pulled up in the drive with certain value so that the Vol is obtained to run with a host that has large value of
pull up resistor. - CS0 and - CS1 are also pulled up for better noise immunity.
Table 10.3-2 Signal treatment
SIGNAL
Driven by
TYPE
By host
By drive
- RESET
Host
TP
10k
PU
DD 0:15
bi-direction
TS
DMARQ Drive TS
5.6
k
Ω PD
- DIOR
Host TS
-DMARDY
HSTROBE
- DIOW
Host TS
STOP
IORDY
Drive
TS
4.7 k
Ω PU
-DDMARDY
DSTROBE
CSEL
Host GND
10
k
Ω PU
- DMACK
Host TP
INTRQ Drive TS
10
k
Ω PD
- IOCS16
Drive
OD
1.0 k
Ω PU
1.2 k
Ω PU
DA 0:2
Host TP
- PDIAG
Drive TS
10
k
Ω PU
- CS0 - CS1
Host TP
- DASP
Drive
OD
10 k
Ω PU
TP = Totem Pole, TS = Tri-State, PD = Pull Down, PU = Pull-Up, OD = Open Drain