beautypg.com

Tyco Electronics LD9000 Series User Manual

Page 125

background image

USB HID Keyboard Emulation Swipe Reader

20

SS_TK3_ISO_ABA PROPERTY

Property ID:

8

Property Type:

Byte

Length: 1

byte

Get Property:

Yes

Set Property:

Yes

Default Value:

2B (hex) ‘+’

Description:

This character is sent as the track 3 start sentinel for cards that have track 3
encoded in ISO/ABA format. If the value is 0 no character is sent. If the
value is in the range 1 – 127 then the equivalent ASCII character will be sent.


This property is stored in non-volatile EEPROM memory so it will not change when the unit is
power cycled. When this property is changed, the unit must be power cycled to have these
changes take effect. If a value other than the default value is desired, it can be set by the factory
upon request.

SS_TK3_AAMVA PROPERTY

Property ID:

9

Property Type:

Byte

Length: 1

byte

Get Property:

Yes

Set Property:

Yes

Default Value:

23 (hex) ‘#’

Description:

This character is sent as the track 3 start sentinel for cards that have track 3
encoded in AAMVA format. If the value is 0 no character is sent. If the
value is in the range 1 – 127 then the equivalent ASCII character will be sent.


This property is stored in non-volatile EEPROM memory so it will not change when the unit is
power cycled. When this property is changed, the unit must be power cycled to have these
changes take effect. If a value other than the default value is desired, it can be set by the factory
upon request.

SS_TK3_7BITS PROPERTY

Property ID:

10 (0A hex)

Property Type:

Byte

Length: 1

byte

Get Property:

Yes

Set Property:

Yes

Default Value:

26 (hex) ‘&’

Description:

This character is sent as the track 3 start sentinel for cards that have track 3
encoded in 7 bits per character format. If the value is 0 no character is sent. If
the value is in the range 1 – 127 then the equivalent ASCII character will be
sent.