Figure 6: anti-tip bracket, Note, Figure 7: placement of anti-tip bracket (top view) – Thermador PRO-HARMONYTM PRD30 User Manual
Page 13: Mounting anti-tip bracket, Secure to floor or wall stud
English 11
Note:
48“ Ranges do not require the Anti-Tip Bracket. This is due
to the size and weight distribution of the 48“ models.
•
Prepare holes at fastener locations as identified below:
•
For walls, wall studs, or floors composed of solid
wood or metal, drill 1/8" pilot holes.
•
For walls or floors composed of drywall, sheet-rock
or other soft materials, drill 3/16" holes to a mini-
mum depth of 1-3/4", then tap plastic anchors into
each of the holes using a hammer.
•
For walls or floors composed of concrete or con-
crete block, drill 3/16" holes to a minimum depth of
1-3/4", then tap concrete anchors into each of the
holes using a hammer.
•
For walls or floors having ceramic tile covering, drill
3/16" holes through the tile only, then drill into the
material behind the tile as indicated immediately
above.
•
If the range is moved to a new location, the Anti-Tip
Device must be removed and reinstalled.
Mounting Anti-Tip Bracket
The alternative floor mounted bracket shall be installed as
follows:
1.
Place bracket on floor in position shown in Figure 7
(Bracket may be used in either corner of the installation
area).
2.
Secure to floor or wall stud.
3.
Later, when the unit is installed, the adjustable leg will
slide under the bracket.
Figure 6: Anti-tip Bracket
Figure 7: Placement of Anti-Tip Bracket (Top View)