14-11

14. OPERATING PROCEDURES

14.6 TARE/SAVE FUNCTION PROCEDURES

14.6 TARE/SAVE FUNCTION PROCEDURES

Menu: REG., M.DOWN, or REWRAP
Mode: WEIGH or FIX (Tare % function is available in WEIGH mode only.)

There are two kinds of tare subtraction procedures, one is “Direct tare”, the other is “Preset tare”. The
SAVE key is used to save the tare, unit price, and PLU data after taking a commodity from the platter.

0.200 lb

T

T

%

%

%

C

1

0

0

1

0

0

0

T

2

0

0

1

0

0

PLU

SAVE

PRT

*

C

Remove the commodity
together with the container.

Remove the commodity
together with the container.

The label is issued.

PLU

PLU

NOTES:

1. Tare subtraction is available up to 2.000 lb. for US type, and up to 1.000kg (2.205lb) for the

CA type. When tare subtraction is in operation, however, the scalable range for net weight
becomes less by the amount of the tare. (Net weight = Gross weight-Tare)

2. Preset tare must be a multiple of 2 g for CA/QR type (Kg scale) and a multiple of 0.005 lb

for US/CA type (Lb scale).

3. The tare % function is available when the Initial Setting #8-7 is set to 1. The speed key #70

will function as the % key (Refer to page 5-3). Set a tare % within the range from 0.0 to 99.9.

4. When a commodity is placed on the platter and the calculated tare exceeds the maximum,

a “TARE WEIGH OVER” error will occur.

Place a container on
the platter

US type

Place a container on
the platter.
(Ex. 0.200 lb)

Press:

Enter the PLU #.

Press:

The PLU data and tare
are saved.

Place a commodity on
the platter. (Ex. 1.000 lb)

MANUAL:

:AUTO

Press:

Tare %

Press:

Tare %

Press:

CA type

Press:

Press:

Press:

Press: