Toshiba TEC SL-9000-ESB-X SERIES User Manual
Page 31
11-6
11. PROGRAMMING PROCEDURES
11.2 PLU DATA SETTING
Pressing the
↓
key instead of the
ENTER
key proceeds to the next menu. Pressing the
↑
key
returns to the preceding menu.
Verification label of PLU data
NET WT.
SELL BY
PACKED ON
PRICE lb
T1.000
T15.0%
C
Commodity Name
Compulsory Tare
Shelf Life
Price
UPC#
Quantity
PLU#
Preset Tare
Mode Flag
NOTES:
1. A UPC code is made up of a combination of an entered code and an AUTO CODE. Be sure
to add some - characters to the end of the AUTO CODE, or all entered codes will be
ignored and an AUTO CODE will become an UPC code (see ex. 1).
ex. 1) enter code:
456
ex. 2) enter code
4567
ex. 3) enter code: 123456
AUTO CODE: 123....
AUTO CODE: 123....
AUTO CODE:
987
code#: 123456
code#: 123567
code#: 987
2. When there is no area to store PLU data, an error occurs when pressing the ENTER key.
3. Changing a PLU# to number to which other PLU data is set will result in an error.
4. Unit price flag may be selected as follows:
1)
In case of lb scale
a. INSERT1 key
: $ per lb
b. DELETE (A) 1/2 key : $ per 1/2 lb
c. RETURN 1/4 key
: $ per 1/4 lb
2)
In case of kg scale
a. INSERT 1 key
: $ per 100 g or Kg (CA/QR type only)
5. Tare limit should be a multiple of 5 (5, 10, 15...), up to 2.000 lb for US type and a mutiple of 2
(2, 4, 6, 8...), up to 1.000 Kg for CA/QR type.
6. Safe handing instructions can be printed on 57-mm wide labels only. Safe handing
instructions are printed on labels formatted for ingredient messages. Only ingredient
message labels with 13 or more lines can be used to print safe handling instructions.
The only available print format for this function on the ESB-X is format # 48.
7. Tare % indicates a percentage of tare in gross weight, which is available when the Initial
Setting #8-7 is set to 1.
8. When setting open price in the count mode (Initial Setting #1-6: 1), set zeros as quantity and
unit price.
↓
↓
↓
Preset % Tare
TEC STORE
(TEL) 0123-45-6789