FAULT DIAGNOSIS BY REMOTE CONTROLLER
In the ARC433A series, the temperature display sections on the main unit indicate corresponding codes.

1. When the TIMER CANCEL button is held down for 5 seconds, a “

” indication flashes on the

temperature display section.

2. Press the TIMER CANCEL button repeatedly until a continuous beep is produced.

• The code indication changes as shown below, and notifies with a long beep.

NOTE

Fault diagnosis

CODE

MEANING

SYSTEM

00

NORMAL

U0

REFRIGERANT SHORTAGE

U2

DROP VOLTAGE OR MAIN CIRCUIT OVERVOLTAGE

U4

FAILURE OF TRANSMISSION (BETWEEN INDOOR UNIT AND OUTDOOR UNIT)

INDOOR

UNIT

A1

INDOOR PCB DEFECTIVENESS

A5

HIGH PRESSURE CONTROL OR FREEZE-UP PROTECTOR

A6

FAN MOTOR FAULT

C4

FAULTY HEAT EXCHANGER TEMPERATURE SENSOR

C9

FAULTY SUCTION AIR TEMPERATURE SENSOR

OUTDOOR

UNIT

EA

COOLING-HEATING SWITCHING ERROR

E5

OL STARTED

E6

FAULTY COMPRESSOR START UP

E7

DC FAN MOTOR FAULT

E8

OPERATION HALT DUE TO DETECTION OF INPUT OVER CURRENT

F3

HIGH TEMPERATURE DISCHARGE PIPE CONTROL

H6

OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR

H8

CT ABNORMALITY

H9

FAULTY SUCTION AIR TEMPERATURE SENSOR

J3

FAULTY DISCHARGE PIPE TEMPERATURE SENSOR

J6

FAULTY HEAT EXCHANGER TEMPERATURE SENSOR

L4

HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK

L5

OUTPUT OVERCURRENT

P4

FAULTY INVERTER CIRCUIT HEATSINK TEMPERATURE SENSOR

1.A short beep and two consecutive beeps indicate non-corresponding codes.
2.To cancel the code display, hold the TIMER CANCEL button down for 5 seconds. The code dis-

play also cancel itself if the button is not pressed for 1 minute.