beautypg.com

Install system at remote site, Survey site, Install shelves – Texas Instruments 3000 MCU User Manual

Page 17: Rack mount, Wall mount, 1 survey site, 2 install shelves

background image

SpectraLink Corporation

T1 Remote Module Installation

Link WTS – Link 3000 MCU

4. Install System at Remote Site

4.1 Survey

Site

Check the site to be sure pre-installation work has been completed correctly. This
includes:
• Location chosen for the shelves is adequate.
• Rack (if rack mounted) is properly secured or backboard (if wall mounted) is properly

prepared.

• Power is available.
• Wiring to Base Station locations has been pulled and correctly terminated.
• Phone lines for the Wireless Telephones are installed and properly terminated.
• Telephone system administrator is available to program the existing telephone

system.

4.2 Install

Shelves

Rack Mount

To install shelves in the rack, slide the shelves into the rack and secure them to the rack
using eight screws, 1/4 inch minimum length.

Wall Mount

At this point in the installation process, there should be a backboard securely fastened to
the wall and mounting screws partially inserted into the backboard. See Link WTS – Link
3000 MCU: Installation
for more information.
To attach the shelves to the wall:

1. Remove all cards from the shelf. Do not mount the shelf with cards installed.

Cards contain components that may be damaged by electrostatic discharge.
Before handling any of the cards, attach the grounding strap (included in the
Administration Kit) to your wrist, and attach the other end of the strap to
ground. Handle cards only by their edges. Do not touch connector contact
areas. Do not lift cards by any of the components. Do not lay cards down on
their component sides. When laying a card down, place it component side
up, on top of the anti-static bag in which it was shipped.

2. Position the MCS300 so that the six mounting screws are aligned with the six

keyhole openings in the back of the shelf.

3. Slide the shelf down onto the screws to lock the shelf into place. Check that all

six screws are properly locked.

4. Tighten all six screws fully.

Part Number: 72-0059-06-E.doc

Page 17