T1 Remote Module Installation
Link WTS – Link 3000 MCU
Network Clocked T1 Facilities
If the T1 facilities are Network Clocked, one T1 Remote Module must be designated as
the Master Clock Source. Connect the
Sync IN
port on this T1 Remote Module to
AUX
port
A
on the Intershelf Junction Panel. Note, this shelf must also be designated as the
Master Clock in the system configuration.
Connect T1 Facilities
Connect the RJ48C jack from the
CSU
port at the local end to the
DS1 A
and
DS1 B
ports on the T1 Remote Module. Port A controls slots 3-7 on the remote module at the
far end. Port B controls slots 8-12.
The following diagram shows the T1 Remote Module connections at the LOCAL site.
Part Number: 72-0059-06-E.doc