Available Through:

Toshiba’s Black Gold UPS is built for harsh industrial environments subjected to shock and vibration.

The Black Gold Series features a robust steel enclosure (3U), an intelligent LED status display, an input

isolation transformer, hot-swappable slide-out battery modules, front output receptacle breakers, RS-232C

and remote contacts. This system combines true on-line technology, state-of-the-art electronics and the

Toshiba name to offer one of the most reliable UPS on the market.

Black Gold Series Specifications

General
Information

Model Number

UC1A1A020C6RKBIG

UC1E1E020C5RKBIG

Rated Output Capacity

2000 VA (1400 W)

External Dimensions (W x D x H)

16.75 in x 24.0 in x 5.25 in (425 mm x 610 mm x 133 mm)

Input

Rated Voltage

120 VAC, Single Phase

230 VAC, Single Phase

Voltage Variation

+10% to -30%

Rated Frequency

50/60 Hz

Power Factor

Greater than .98 when in inverter mode

Harmonic Currents

Less than 5% THD

Battery

DC Nominal (Voltage Range)

72 VDC (57.6 – 82.8 VDC)

Float Charge (Regulation)

82.8 VDC (±2%)

Ripple Voltage

0.5 % R.M.S.

Rated Back-up Time when fully charged at
77

o

F

(25

o

C

)

6 min at full load

18 min at half load

Recharge Time

Maximum 24 hrs to 100% (90% recharge after 8 hrs)

Rated Charge Time

0.40 Amps

Type of Batteries

Sealed lead-acid

Output

Rated Voltage (Single Phase)

120 VAC

230 VAC

Output Voltage Regulation

±3%, steady state

Output Frequency

50/60 Hz ±0.5% in free running mode

(Line sync range ±1 Hz)

Output Voltage Waveform

Computer-grade sinewave with less than 3.0% THD

Rated Current (RMS)

16.6 Amps

8.6 Amps

Rated Power Factor

.7 lagging

Maximum Overload Capacity

150% for 60 sec

Voltage Transient Characteristic

± 5% under 100% load step change

Crest Factor

3.0

Environment

Operating Temperature

32 to 104

o

F

(0 to 40

o

C

), optimal at 77

o

F

(25

o

C

)

Storage Temperature

-4 to 104

o

F

(-20 to 40

o

C

)

Operating Humidity

30% to 90% (no condensation)

Altitude

Less than 3000 ft (1000 m) above sea level

Net Weight

119 lbs (54 kg)

111 lbs (50 kg)

Acoustical Noise

<45 dB at maximum output, measured 3.3 ft (1 m) from front panel

Efficiency (AC-DC-AC)

82%

Bypass

An automatic transfer of load to bypass switch (< 4mS-transfer time) may be caused by an overload of the inverter output, or by an
internal fault condition. Also, the load can be manually transferred to bypass by putting the rocker switch in the STOP position.

Interface

Dry Contact

Bypass, battery low, and on-line signals

DB9 male connector

RS232 ASCII

Pins 1 through 8

DB9 female connector

Receptacle

3 5-15R (Duplex)

3 IEC320 (Duplex)

Options

RemotEye I

I

®