(1. 3. 4) Changing each setting in PW SR mode

-- SHUTTER --

MODE

E.TRG

E.TRG

PW SR

TRG.P
PART

OFF

• Partial scanning switch
OFF/60fps/90fps/E.60fps/E.90fps

Input trigger pulse : positive polarity
Input trigger pulse : negative polarity

1P SNR, 1P SR, PW SNR, PW SR, RR

• Input trigger pulse setting at PW SNR and PW SR

• Shutter mode MANU, SS, E.TRG

• E.TRG mode

Move up down
By pushing
MENU UP, DOWN

Set by pushing
DATA UP, DOWN

(a) Changing the polarity of inputting trigger pulse setting

1 Set the "

→" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.

2 Select either

,

by pushing [DATA UP], [DATA DOWN] buttons.

Note:

The longer the storage time with extended exposures, the more visible certain characteristics of CCD
cameras become: fixed pattern noise, white pixels, etc.