background image

5

4

After Initial Pairing
2-1) Before activating the scale, make sure the corresponding Bluetooth device is turned on.

2-2) Press “OUTPUT” key to turn on the scale, as noted by a single beep.

The scale will find the previous corresponding Bluetooth device.
* If unable to establish pairing or if no response from the corresponding Bluetooth device within

30 seconds, an error will show on the scale (step 3-1).

Specification

Output Data

Note : • The data are divided with commas (,) for each data.

• The terminator (end of data) is CR (ASCII code 0

(zero)

D), LF (ASCII code 0

(zero)

A).

[Output example (in the case to lb unit)]

Control Data

Control Data

Model No

Weight Data

Checksum

CR

{0

,

16

,

˜0

,

1

,

MO

,

"HD-351BT"

,

Wp

,

xxx.x

,

CS

,

xx

,

0

(zero)

D

LF

0

(zero)

A

Signal Speed

Heade

Output data (ASCII code)

Substance

Control Data

{0

Fix to 16

2bytes fixed

Control Data

˜0

Fix to 1

1bytes fixed

Model No.

MO

"HD-351BT"

10bytes fixed

Weight
Data

kg

lb

St-lb

Wk

XXX.X

3 - 5bytes variable length

Wp

XXX.X

3 - 5bytes variable length

Ws

XX.YY.Y

5 - 7bytes variable length X:st Y:lb

Checksum

CS

XX

2bytes fixed

Start Bit

9600 bps

1 bit

Data Bit Length

8 bits

Parity

None

Stop bit

PIN

1 bit

0000

2-3) A successful pairing operation between scale and the corresponding Bluetooth device will be

noted by a double beep.

2-4) The display will change to the zero calibration display.

2-5) The display will then changed to the waiting display. Step onto the scale and measure weight.

2-6) The weight result will flash after measurement is completed. The weight data will then be sent to

the corresponding Bluetooth device.

2-7) To continue with more weighting’s, press “OUTPUT” key (Step 2-4).

2-8) The scale will automatically shut off when ---

* The user remains on the scale for 30 seconds.
* The user get off from the scale, and then after 30 seconds.

Error Process
3-1) Failure to “PAIR” display.

3-2) Display will change to zero calibration display.

3-3) The display will then change to the waiting display. Step onto the scale and measure weight, or

to reattempt Bluetooth pairing press “OUTPUT” key (step 1-2).

3-4) The weight result will flash after measurement is completed.

* The weight result data will not be sent to the corresponding Bluetooth device.
* To reattempt Bluetooth pairing, press “OUTPUT” key (step 1-2).

3-5) The scale will automatically shut off when ---

* The user remains on the scale for 30 seconds.
* The user get off from the scale, and then after 30 seconds.

OR

8. Output Data Format